Influence of the Positioner Installing to Burnup Measurement |
ZHANG Ming1,2,YAN Wei-hua2,ZHANG Li-guo3,XIAO Zhi-gang2,YANG Yuan-di1 |
1.National Institute of Metrology, Beijing, 100013 China
2.Department of Physics, Beijing, 100084 China
3.Institute of Nuclear and New Energy Technology, 100084 China |
|
|
Abstract In order to improve the benefits of nuclear power plants and make full use of the nuclear fuels, it is necessary to perform the on-line nondestructive burnup measurement to the fuel pebbles from the high temperature gas-cooling reactor.Numerical calculations are carried out to simulate the absorptions of positioner materials on γ-rays.By analyzing the calculated results, it reveals that design parameters of the perforation can bring a larger variation to the intensity of radiations emitting from the positioned and further affect the on-line burnup measurement; Moreover, the intensity of radiations is not sensitive to the deviation between the positioner and perforation in the vertical direction.
|
|
|
|
|
|
[1]Terremoto L A A, Zeituni C A,et al.Gamma-ray spectroscopy on irradiated MTR fuel elements[J].Nucl Instr and Meth, 2000,A450:495-514.
[2]李桃生.高温气冷堆在线燃耗测量系统研究与初步设计[D].北京:清华大学,2006.
[3]张立国,李桃生,等.球床式高温气冷堆在线燃耗测量中239Pu的影响分析[J].核动力工程,2008,29(4),88-92.
[4]张立国,尚仁成,等.冷却衰变时间对球床模块式高温气冷堆在线燃耗测量的影响分析[J].核动力工程,2009,30(3):43-46. |
|
|
|