The Establishment of Installation Effect Database for Multipath Ultrasonic Flowmeters |
HU He-ming,MENFG Tao,ZHANG Liang,WANG Chi |
National Institute of Metrology, Beijing 100013 |
|
|
Abstract An installation effect database for multipath ultrasonic flowmeters based on CFD flow filed has been established.The extra errors under different installation conditions can provided to guide the flowmeter selection and designing downstream of installations, and the path velocity distributions under different installation conditions can be also provide for the flowmeter daily check.The installation effects database is easy to use for engineers while the CFD is difficult to carry out.
|
|
|
|
|
|
[1]胡鹤鸣, 王池, 孟涛.多声路超声流量计积分方法及其准确度分析[J].仪器仪表学报, 2010, 31(6):1218-1223.
[2]胡鹤鸣, 王池, 孟涛.复杂流场对三峡超声流量计准确度影响的CFD分析[J].计量学报, 2010, 31(6A):63-68.
[3]国家质量监督检验检疫总局,JJG 1030-2007 超声流量计[S].2007.
[4]IEC 60041-1991.International code for the field acceptance test of hydraulic turbines [S].
[5]ASME PTC18-2002.Hydraulic turbines and pump- turbines performance test codes [S].
[6]郑丹丹,张朋勇,孙立军, 等.单弯管下游超声流量计的安装和测量性能研究[J].仪器仪表学报, 2010, 31(7):1601-1607.
[7]吴志敏, 苏满红, 叶玮渊.时差法超声波流量计流速修正系数的数值模拟[J].工业计量, 2008, 18(4): 1-4.
[8]Staubli T, Luescher B, Gruber P, et al.Optimization of acoustic discharge measurement using CFD [J].International Journal on Hydropower & Dams,2008; 15(2): 109-112. |
|
|
|