Acta Metrologica Sinica  2011, Vol. 32 Issue (3): 253-257    DOI: 10.3969/j.issn.1000-1158.2011.03.13
Current Issue | Archive | Adv Search |
Application of the Quartz-flexure Accelerometer to the Development of Ultra-low Frequency Vibration National Primary Standard Device
YU Mei1,LIU Ai-dong1,HE Wen2,YANG Li-feng1,HU Hong-bo1,ZUO Ai-bin1,MA Ming-de1
1.National Institute of Metrology, Beijing 100013, China
2.Zhejiang University, Hangzhou Zhejiang 310027, China
Download: PDF (458 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  The improved quartz-flexure accelerometer with independent developed condition-amplifier is adopted as the vibration pickup sensor in ultra-low frequency vibration feedback control, and as the standard implement for performance measuring of ultra-low frequency vibration primary standard device. The distortion of vibrator output acceleration waveform is decreased effectively, and the effect of environmental vibration is suppressed to some extent. The acceleration distortion is less than 1% above 0.002 Hz.It solves the measurement means problem caused by without measuring sensor below 1Hz.The stability and repeatability meet requirements of standard devices.It is considered that it can be used as the standard implement of calibration and the check standard for low frequency or ultra-low frequency vibration national primary standard and standard devices.
Key wordsMetrology      Ultra-low frequency vibration primary standard      Quartz-flexure accelerometer      Negative-feedback      Distortion      Sensitivity     
PACS:  TB936  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
YU Mei
LIU Ai-dong
HE Wen
YANG Li-feng
HU Hong-bo
ZUO Ai-bin
MA Ming-de
Cite this article:   
YU Mei,LIU Ai-dong,HE Wen, et al. Application of the Quartz-flexure Accelerometer to the Development of Ultra-low Frequency Vibration National Primary Standard Device[J]. Acta Metrologica Sinica, 2011, 32(3): 253-257.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2011.03.13     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2011/V32/I3/253
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech