Study on Volume Measurement Method for Spherical Tank Based on Three Dimension Laser Scanning Principle |
WEI Kai1,SONG Shu-gu1,LIU Zi-yong2 |
1.Qingdao Institute of Measurement and Testing, Qingdao, Shandong 266101, China;
2. National Institute of Metrology, Beijing 100029, China |
|
|
Abstract The method of sample and analysis for three dimension data cloud was discussed, and the main content included data sample principle, noise reduction, gross error identification, radius fitting and volume calculation. One preliminary experiment was done to test this method. The experimental result of one 1000m3 sphere tank showed that there was consistency between total station method and data cloud analysis method for the measurement on the level diameter of spherical tank with one difference 1mm, but for vertical diameter one big difference 16.1mm occurred between the data from two methods. The measurement uncertainty of laser scanning method used for tested the sphere tank volume calibration is 0.4% (k=2)。
|
|
|
|
|
|
[1]廉育英. 容量计量技术[M]. 北京:北京计量出版,2006.
[2]廉育英, 刘子勇, 何力, 等. 立式金属计量罐大容量的新测量方法[J]. 计量学报,1988, 9(4):241-247
[3]许红星. 我国能源利用现状与对策[J]. 中外能源,2010,15(1):3-14.
[4]国国家质量监督检验检疫总局.JJG642—2007, 球形金属罐容量[S]. 2007.
[5]王金涛, 刘子勇, 张珑, 等. 基于点云分析的大型立式液态石化产品储罐容量计量方法研究[J]. 计量学报,2011, 32(2):110-113
[6]王金涛, 刘子勇, 张珑,等.卧式能源储罐容量计量中激光测量方法的研究[J]. 计量学报,2011,32(3):262-265.
[7]郑德华.三维激光扫描数据处理的理论与方法[D]. 上海:同济大学, 2005.
[8]Davis T G. Total least squares spiral curve fitting[J].Journal of Surveying Engineering, 1999, 125(4):159-173. |
|
|
|