Acta Metrologica Sinica  2024, Vol. 45 Issue (8): 1089-1095    DOI: 10.3969/j.issn.1000-1158.2024.08.01
Current Issue | Archive | Adv Search |
Low Light Level Spectral Responsivity Measurement System
LÜ Liang1,LUO Yupeng2,JIANG Xiaomei1,LIN Xiaofeng1,PANG Bowen1
1. Optic Division, National Institute of Metrology, Beijing 100029, China
2. School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
Download: PDF (639 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  To meet the spectral responsivity calibration requirements of photon counting detectors, a low light level spectral responsivity measurement system is established. The feature of this system is that it can achieve spectral comparison measurement at pW monochromatic light power level. An adjustable luminance source is designed, and it is tightly coupled with the dispersion subtractive double grating monochromator to achieve power variable monochromatic light output with six orders, which can be applied to the linear working range of different photon detectors, covering the wavelength range 330~1100nm. The light-tight designation of the light path enables the system to work under normal lighting conditions, reducing the experimental environment requirements. Based on a standard detector integrated with fA grade current amplifier, the spectral responsivity measurement of the photon detectors at 1×106photons/s count rate level is achieved. The controlling and data acquisition software are developed using LabView platform, which realizes the whole process of measurement automation. The characteristics experiment of the system has been carried out, and the relative spectral responsivity of photon detector are calibrated in the wavelength range from 330~1100nm with relative expanded uncertainty is (2.5~3.8)%, k=2.
Key wordsoptical measurement      spectral responsivity      spectral comparison      low light level measurement      photon counting      uncertainty     
Received: 04 February 2024      Published: 05 September 2024
PACS:  TB96  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Lü Liang
LUO Yupeng
JIANG Xiaomei
LIN Xiaofeng
PANG Bowen
Cite this article:   
Lü Liang,LUO Yupeng,JIANG Xiaomei, et al. Low Light Level Spectral Responsivity Measurement System[J]. Acta Metrologica Sinica, 2024, 45(8): 1089-1095.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2024.08.01     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2024/V45/I8/1089
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech