Impacts of Tissue-equivalent Liquid Properties onSAR and the Correction Model |
ZHOU Xin,LI Anxiang,PANG Xinhua,DOU Lilan,TANG Wei,SHEN Qingfei,WU Tong |
National Institute of Metrology, Beijing 100029, China |
|
|
Abstract To determine a correction model that can be used to correct the measured specific absorption rate (SAR) in a homogeneous phantom when its dielectric properties deviates from standardized target values. The correction model is established based on the method of electromagnetic numerical simulation. The method is verified by comparison with the data in the IEC 62209\IEEE 1528 standards at 835MHz. Based on the method, correction models at 3.5 and 28GHz, which are the candidate bands for the future communication systems, are proposed. Employing the correction models reduces the SAR measurement uncertainty, thereby improving the reproducibility of SAR compliance assessment between laboratories. Another benefit is that it enables the use of broadband tissue-equivalent liquids, whose dielectric parameters are not currently within the tight tolerances of existing standards. The use of broadband liquids reduces the cost of SAR measurement.
|
Received: 12 April 2023
Published: 03 April 2024
|
|
|
|
|
|
ZHAO N, WU T, SHEN Q F, et al. Design of electromagnetic radiation capability verification of mobile communication base station [J]. Measurement Technology, 2013(12): 10-12.
|
[3] |
陈天华. PLC电磁辐射及应用性能测试 [J]. 计量学报, 2008, 29(3): 251-256.
|
[4] |
石晓玲, 袁慎芳, 邱雷. 抗电磁干扰压电夹层优化设计 [J]. 计量学报, 2012, 33(5): 457-462.
|
[5] |
武彤, 沈庆飞. 实验室之间辐射骚扰场强比对的设计 [J]. 电子质量, 2007(8): 82-84.
|
|
CHEN T H. PLC electromagnetic radiation and application performance testing [J]. Acta Metrologica Sinica, 2008, 29(3): 251-256.
|
|
WU T, SHEN Q F. Design of inter-laboratory radiated nuisance field strength comparison [J]. Electronics Quality, 2007(8): 82-84.
|
[2] |
武彤, 梅晓蕾, 马文华. 移动通信基站电磁辐射测量示范系统的规范设计 [J]. 电信工程技术与标准化, 2016, 29(2): 50-53.
|
|
SHI X L, YUAN S F, QIU L. Optimized Design for Piezoelectric Layer of Anti-electromagnetism Interference[J]. Acta Metrologica Sinica,2012, 33(5): 457-462.
|
[7] |
IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques: IEEE Std 1528—2013[S].
|
[8] |
Human Exposure to Radio Frequency Fields from Hand-Held and Body Mounted Wireless Communication Devices—Human Models, Instrumentation, and Procedures—Part 1: Procedure to Determine the Specific Absorption Rate (SAR) for Hand-Held Devices Used in Close Proximity to the Ear (Frequency Range of 300 MHz to 3GHz): IEC Standard 62209[S].
|
[11] |
FUKUNAGAK, WATANABE S, YAMANAKA Y. Dielectric properties of tissue-equivalent liquids and their effects on specific absorption rate [J]. IEEE Transactions on Electromagnetic Compatibility, 2004,46(1): 126-129.
|
[13] |
WU T, ZHOU X, SHEN Q F, et al. Proficiency Testing for Complex Permittivity Measurements of Tissue Equivalent Liquid Used in SAR Assessment [J]. IEEE Access, 2020(8): 210592-210596.
|
[15] |
李明洋. HFSS电磁仿真设计应用详解 [M]. 北京:人民邮电出版社, 2010.
|
[17] |
ZHOU X, ZHONG Z, BIAN X, et al. Measurement and Analysis of Channel Characteristics in Reflective Environments at 3.6GHz and 14.6GHz [J]. Applied Sciences, 2017, 7(2): 165.
|
[1] |
赵楠, 武彤, 沈庆飞, 等. 移动通信基站电磁辐射能力验证的设计 [J]. 计量技术, 2013(12): 10-12.
|
|
WU T, MEI X L, MA W H. Specification design of electromagnetic radiation measurement demonstration system for mobile communication base station [J]. Telecom Engineering Technics and Standardization, 2016, 29(2): 50-53.
|
[6] |
IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz: IEEE Std C95.1—2005[S].
|
[9] |
无线通信终端电磁辐射(SAR)测量系统校准规范: JJF (通信) 019—2015 [S].
|
[16] |
WANG Y, LI J, HUANG L, et al. 5G mobile: Spectrum broadening to higher-frequency bands to support high data rates [J]. IEEE Vehicular technology magazine, 2014, 9(3): 39-46.
|
[18] |
TANG M C, SHI T, ZIOLKOWSKI R W. A Study of 28GHz, Planar, multilayered, electrically small, broadside radiating, huygens source antennas [J]. IEEE Transactions on Antennas and Propagation, 2017, 65(12): 6345-6354.
|
[19] |
HONG W, BAEK K H, LEE Y, et al. Study and prototyping of practically large-scale mmWave antenna systems for 5G cellular devices [J]. IEEE Communications Magazine, 2014, 52(9): 63-69.
|
[10] |
ICNIRP. International Commission on Non-ionizing Radiation Protection Guidelines for limiting exposure to electromagnetic fields(100kHz to 300GHz) [J]. Health Phys, 2020, 118: 483-524.
|
[12] |
DOUGLAS M G, KANDA M Y, LUENGAS W G, et al. An Algorithm for Predicting the Change in SAR in a Human Phantom Due to Deviations in Its Complex Permittivity [J]. IEEE Transactions on Electromagnetic Compatibility, 2009, 51(2): 217-226.
|
[14] |
DOUGLAS M G, CHOU C K. Enabling the use of broadband tissue equivalent liquids for specific absorption rate measurements [C]//IEEE. 2007 IEEE International Symposium on Electromagnetic Compatibility. 2007: 1-6.
|
|
|
|