|
|
Multi-target Vital Sign Detection Based on FMCW Radar |
PAN Liang,LIU Kang,ZHANG Yuanhui |
College of Mechanical and Electrical Engineering,China Jiliang University, Hangzhou, Zhejiang 310018, China |
|
|
Abstract The detection of non-contact human vital signs (such as respiration and heartbeat) based on radar, which has significant importance across various fields. One of these challenges, which the work seeks to solve, is the detection of multiple human targets and the filtering of interference, as well as the elimination of heartbeat signal interference in complex scenarios. To meet this need, a multi-target vital sign detection method, which relies on frequency modulated continuous wave (FMCW) radar, is proposed. After first introducing the radar detection principle and signal model, the entire radar signal processing flow is elucidated, which consists of multi-target distance unit detection, phase extraction, and vital sign signal extraction. In the process of multi-target distance detection, where challenges often arise, an improved Cell Averaging Constant False Alarm Rate (CA-CFAR) algorithm is proposed, a method that not only features adaptive detection thresholds but also solves the problem of repeated distance gate detection near targets in traditional CA-CFAR algorithms, thus achieving multi-target detection. During the vital sign signal extraction process, the Automatic Multi-Scale Peak Detection (AMPD) algorithm is utilized so that breathing and heart rates can be estimated, filtering out invalid peak interferences, which enhances the robustness of heartbeat and respiration rate detection. Finally, through multiple sets of tests, which are conducted to verify the methodology, the average error rates for breathing rate and heart rate detection are found to have reduced by 3.67% and 3.31%, respectively, when compared to commonly used spectral analysis estimation methods, the feasibility and accuracy of the proposed method are validated.
|
Received: 03 August 2023
Published: 22 January 2024
|
|
|
|
|
[3] |
张宁, 李宏军, 于江涛, 等. 用于非接触式生命体征检测的雷达技术研究进展[J]. 半导体技术, 2023, 48(1):1-9+17.
|
[6] |
潘俊, 叶盛波, 史城, 等. 基于先验信噪比估计的超宽带穿墙雷达呼吸信号检测算法研究[J]. 电子与信息学报, 2022, 44(4):8.
|
[7] |
LIU K, DING C, ZHANG Y H. A Coarse-to-Fine Robust Estimation of FMCW Radar Signal for Vital Sign Detection[C]//2020 IEEE Radar Conference (RadarConf20). IEEE. 2020.
|
[13] |
DUAN Z, LIANG J. Non-Contact Detection of Vital Signs Using a UWB Radar Sensor [J]. IEEE Access, 2019, 7:36888-36895.
|
|
WU X Q, YANG S J, HU Z X, et al. Research on the Calibration Method of Vital Sign Simulator [J]. Acta Metrologica Sinica, 2020, 41(12): 1000-1158.
|
|
ZHANG N, LI H J, YU J T, et al. Research Progress of Radar Technology For Non-Contact Vital Sign Detection [J]. Semiconductor Technology, 2023, 48(1):1-9+17.
|
|
YANG J, HUANG J, TAO W. Adaptive Vital Sign Extraction Method Based on FMCW Radar [J]. Radar Science and Technology, 2022, 20(2):187-194.
|
|
ZHANG S Q, DONG X, ZHAI X P, et al. A Signals Feature Extraction Method Based on the EEMD and Chaotic and Its Application [J]. Acta Metrologica Sinica, 2013, 34(2): 1000-1158.
|
[10] |
TARIQ A, GHAFOURI-SHIRAZ H. Vital signs detection using Doppler radar and continuous wavelet Transform [C] //Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP).Rome, Italy, 2011.
|
[15] |
任伟, 侯凯悦, 王刚, 等. FMCW毫米波雷达多人呼吸检测方法[J]. 信号处理, 2021, 37(9):1581-1588.
|
[16] |
代霞. 基于77GHz FMCW雷达的生命体征检测算法研究[D]. 成都:电子科技大学, 2021.
|
|
WU Z J, WEI J Y, HUANG L B, et al. Realtime multi-target vital signs detection based on FMCW radar [J]. Transducer and Microsystem Technologies, 2021, 40(3):112-115.
|
[18] |
SCHOLKMANN F, BOSS J, WOLF M. An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals [J]. Algorithms, 2012(4),doi:10.3390/A5040588.
|
[2] |
TOPFER F, OBERHAMMER J. Millimeter-Wave Tissue Diagnosis: The Most Promising Fields for Medical Applications [J]. IEEE Microwave Magazine, 2015, 16(4):97-113.
|
[9] |
张淑清, 董璇, 翟欣沛, 等. 基于EEMD和混沌的信号特征提取方法及应用[J]. 计量学报, 2013, 34(2): 1000-1158.
|
[17] |
吴志军, 韦金宜, 黄李波, 等. 基于调频连续波雷达的多目标生命体征实时检测[J]. 传感器与微系统, 2021, 40(3):112-115.
|
[1] |
吴思圻, 杨世金, 胡志雄, 等. 生命体征模拟仪计量校准方法的研究[J]. 计量学报, 2020, 41(12): 1000-1158.
|
[8] |
杨俊, 黄俊, 陶威. 基于FMCW雷达的自适应生命信号提取方法[J]. 雷达科学与技术, 2022, 20(2):187-194.
|
|
REN W, HOU K Y, WANG G, et al. Multi-target Respiration Detection Using FMCW Millimeter Wave Radar [J]. Journal of Signal Processing, 2021, 37(9):1581-1588.
|
[5] |
LIANG X L, DENG J Q, ZHANG H,et al. Ultra-Wideband Impulse Radar Through-Wall Detection of Vital Signs [J]. Scientific Reports, 2018,doi: 10.1038/s41598-018-31669-y.
|
[12] |
DRAGOMIRETSKIY K, ZOSSO D. Variational Mode Decomposition [J]. IEEE Transactions on Signal Processing, 2014,62(3):531-534.
|
[4] |
WANG G, MUNOZ-FERREAS J M, GU C, et al. Linear-frequency-modulated continuous-wave radar for vital-sign monitoring [C] //IEEE. Wireless Sensors & Sensor Networks. 2014.
|
|
PAN J, YE S B, SHI C, et al. Study on Respiration Signal Detection Algorithm of Ultra-WideBand Through-wall Radar Based on A Priori Signal-to-Noise Ratio Estimation [J]. Journal of Electronics & Information Technology, 2022, 44(4):8.
|
[11] |
HU W, ZHAO Z, WANG Y, et al. Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor [J]. IEEE Trans Biomed Eng, 2014, 61(3):725-735.
|
[14] |
AHMAD A, ROH J C, WANG D, et al. Vital signs monitoring of multiple people using a FMCW millimeter-wave sensor [C] //IEEE.2018 IEEE Radar Conference (RadarConf18). 2018.
|
|
|
|