Low Phase Noise Microwave Synthesizer for Coherent Population Trapping Atomic Clock |
YAO Ming-hao1,DUAN Jun-yi2,WANG Xue-ying1,HAN Qi-na2,SHI Yang2,ZHOU Kun-li2,RU Ning2,LIU Xiao-chi2,QU Ji-feng2 |
1.College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou, Zhejiang 310018, China
2.Center for Advanced Measurement Science, National Institute of Metrology, Beijing 102200, China |
|
|
Abstract Atomic clock based on coherent population trapping (CPT) could interrogate the atoms without microwave cavity, which significantly reduce the volume of the physical package. One of the main limitations of CPT clock is the phase noise of the microwave synthesizer. Here a low phase nosie microwave synthesizer for CPT clock system is demonstrated. The absolute phase noise of the microwave synthesizer achieved -108dBc/Hz at 200Hz offset frequency. The frequency stability limitation of CPT clock with this synthesizer is calculated to be 8. 2×10-14 with Dick effect formula. This low phase noise microwave synthesizer could be also applied in other types of precision measurement system and standards based on atoms.
|
Received: 26 October 2021
Published: 14 November 2022
|
|
Fund:National Natural Science Foundation of China |
|
|
|
[1]Schwindt P D D, Knappe S, Shah V, et al. Chip-scale atomic magnetometer [J]. Applied Physics Letters, 2004, 85 (26):6409-6411.
[2]Lutwak R, Vlitas P, Varghese M, et al. The MAC-a miniature atomic clock [C]//Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, 2005. IEEE, 2005:6.
[3]Lutwak R. The SA. 45s chip-scale atomic clock-early production statistics [C]//Proceedings of the 43rd Annual Precise Time and Time Interval Systems and Applications Meeting. 2011:207-220.
[4]李天初. 从长度单位米到时间单位秒:稳频激光—飞秒光梳—铯原子喷泉钟—光钟 [J]. 计量学报, 2006,27 (1):1-6.
Li T C. From the unit of length meter to the unit of time second:frequency-stabilized laser-femtosecond optical comb-cesium atomic fountain clock-optical clock [J]. Acta Metrologica Sinica, 2006,27 (1):1-6.
[5]朱江淼, 王星, 高源, 等. 综合多家实验室的原子时标发布系统设计 [J]. 计量学报, 2020, 41 (2):238-242.
Zhu J M, Wang X, Gao Y, et al. Design of Atomic Time Scale Publishing System Integrating Multiple Laboratories [J]. Acta Metrologica Sinica, 2020, 41 (2):238-242.
[6]Jeanmaire A, Rochat P, Emma F. Rubidium atomic clock for Galileo [C]//Proceedings of the 31th annual precise time and time interval systems and applications meeting. 1999:627-636.
[7]Almat N, Gharavipour M, Moreno W, et al. Long-Term Stability Analysis Towards<10-14 Level for a Highly Compact POP Rb Cell Atomic Clock [C]//2019 Joint Conference of the IEEE International Frequency Control Symposium and European Frequency and Time Forum (EFTF/IFC). IEEE, 2019:1-2.
[8]Cao Y, Zhao X, Xie W, et al. A merchandized optically pumped cesium atomic clock [C]//IEEE. 2017 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS). 2017:618-621.
[9]Shi F, Wang X, Xu S, et al. The Engineering Applications of Laser Cooling-Cesium Atomic Fountain Frequency-Standard [C]//China Satellite Navigation Conference. Springer, Singapore, 2019:509-517.
[10]Abdel Hafiz M, Boudot R. A coherent population trapping Cs vapor cell atomic clock based on push-pull optical pumping [J]. Journal of Applied Physics, 2015, 118 (12):124903.
[11]Yun P, Tricot F, Calosso C E, et al. High-performance coherent population trapping clock with polarization modulation [J]. Physical Review Applied, 2017, 7 (1):014018.
[12]Yun P, Li Q, Hao Q, et al. High-performance coherent population trapping atomic clock with direct-modulation distributed Bragg reflector laser [J]. Metrologia, 2021, 58:045001.
[13]Liu W, Li Z, Cheng H, et al. Momentum analysis for metasurfaces [J]. Physical Review Applied, 2017, 8 (1):014012.
[14]Liu X, Yudin V I, Taichenachev A V, et al. High contrast dark resonances in a cold-atom clock probed with counterpropagating circularly polarized beams [J]. Applied Physics Letters, 2017, 111 (22):224102.
[15]段俊毅,朱振东,周亚东,等. 基于衍射光学器件的芯片尺度激光冷却原子研究 [J]. 计量科学与技术, 2021(10):10-14.
Duan J Y, Zhu Z D, Zhou Y D, et al. Chip-scale laser cooling of atoms based on diffractive optics [J]. Metrology Science and Technology, 2021(10):10-14.
[16]刘昆,陈伟亮,宋文霞,等. 基于LabVIEW冷原子喷泉钟控制系统的研制 [J]. 计量科学与技术,2020(8):3-7.
Liu K, Chen W L, Song W X, et al. Development of Control System for Cold Atomic Fountain Clock Based on LabVIEW [J]. Metrology Science and Technology, 2020 (8):3-7.
[17]Rohde U L, Poddar A K. Noise minimization techniques for voltage controlled crystal oscillator (VCXO) circuits [C]//IEEE. 2009 IEEE Radio and Wireless Symposium. 2009:280-283.
[18]Gonzalez G. Foundations of Oscillator Circuit,Ch-IV [M]. London:Artech House Inc, 2007.
[19]Hartnett J G, Locke C R, Ivanov E N, et al. Cryogenic sapphire oscillator with exceptionally high long-term frequency stability [J]. Applied Physics Letters, 2006, 89 (20):203513.
[20]Boudot R, Guérandel S, De Clercq E. Simple-design low-noise NLTL-based frequency synthesizers for a CPT Cs clock [J]. IEEE Transactions on Instrumentation and Measurement, 2009, 58 (10):3659-3665.
[21]Xu J, Lin T, Gan Z Y. A computer controllable microwave signal generator for CPT atomic clock [C]//Applied Mechanics and Materials.2012, 220:2654-2657.
[22]Burtichelov T, Everard J. Latest results in the development of an ultra-low phase noise Rb CPT vapour cell atomic clock [C]// IEEE. 2017 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS). 2017:837-841.
[23]Calosso C E, Gozzelino M, Godone A, et al. Intensity detection noise in pulsed vapor-cell frequency standards [J]. IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2019, 67 (5):1074-1079.
[24]Audoin C, Dimarcq N. A limit to the frequency stability of passive frequency standards due to an intermodulation effect [J]. IEEE transactions on instrumentation and measurement, 1991, 40 (2):121-125.
[25]Audoin C, Santarelli G, Makdissi A, et al. Properties of an oscillator slaved to a periodically interrogated atomic resonator [J]. IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 1998, 45 (4):877-886.
[26]Li W B, Hao Q, Du Y B, et al. Demonstration of a sub-sampling phase lock loop based microwave source for reducing dick effect in atomic clocks [J]. Chinese Physics Letters, 2019, 36 (7):070601.
[27]Mu F Y, Ye B S, Lin J, et al. An L-Band Low Spurious Multi-Tuned Frequency Synthesizer [C]//Advanced Materials Research. 2014, 850:441-444.
[28]Li X, Yun P, Li Q, et al. A low phase noise microwave source for high-performance CPT Rb atomic clock [EB/OL]. https://doi.org/10.1049/ell2.12222.
[29]Li W B, Hao Q, Du Y B, et al. Demonstration of a sub-sampling phase lock loop based microwave source for reducing dick effect in atomic clocks [J]. Chinese Physics Letters, 2019, 36 (7):070601. |
|
|
|