Study on the Influence of Standard Curve Preparation on Heavy Metals Analysis in Drinking Water by Inductively Coupled Plasma Mass Spectrometry Method |
WANG Yi,DENG Xiao-juan,XUE Tao,DU Hai-yan,HU Xiao-xia,LIU Yang |
Analysis and Testing Center, Tianjin University, Tianjin 300072, China |
|
|
Abstract The element contents of lead and nickel in drinking water were determined by ICP-MS method, and uncertainties of the two approaches preparing standard curves including volumetric method and weighing method were evaluated. The sources of uncertainty were analyzed, and the components of uncertainty were evaluated and the expanded uncertainty was synthesized. According to the established uncertainty evaluation method, the relative uncertainty of volumetric method is urel(Pb)=2.8%,urel(Ni)=2.4%; the relative uncertainty of weighing method is urel(Pb)=1.6%,urel(Ni)=1.0%. The established uncertainty evaluation procedure is suitable for the determination of heavy metal elements in drinking water by ICP-MS. By comparing the uncertainty and relative component contribution of the volumetric method and weighing method, improvements were proposed from the perspective of standard solution configuration. The scientific basis for strengthening the detection of heavy metals in drinking water was provided and the safety of water quality was ensured.
|
Received: 21 September 2020
Published: 30 June 2022
|
|
|
|
|
[1]农永光, 胡刚. ICP-MS在检测水中的重金属元素当中的应用 [J]. 北方环境, 2011, 23 (11): 187.
Nong Y G, Hu G. Application of ICP-MS in detection of heavy metals in water [J]. Northern Environment, 2011, 23 (11): 187.
[2]王范盛, 金衍健, 严忠雍, 等. 生活饮用水中重金属铅的检测方法研究 [J]. 广州化工, 2015 (15): 126-127.
Wang F S, Jin Y J, Yan Z Y, et al. Advances in Determination of Lead in Drinking Water[J]. Guangzhou Chemical Industry. 2015(15): 126-127.
[3]王金花, 范思艺. 电感耦合等离子体质谱法检测生活饮用水中的铅、 锰、 铬、 铝残留量 [J]. 能源与环境, 2020 (2): 71-72.
Wang J H, Fan S Y. Determination of lead, manganese, chromium and aluminum residues in drinking water by inductively coupled plasma mass spectrometry [J]. Energy and environmental, 2020 (2): 71-72.
[4]陈仁杰, 黄婷婷, 吕良勇, 等. ICP-MS测定陶瓷片密封水嘴浸泡液中镉含量的不确定度分析 [J]. 计量学报, 2018, 39 (6): 914-917.
Chen R J, Huang T T, Lv L Y, et al. Evaluation of Uncertainty in Measurement of Cadmium in Immersion Solution of Ceramic Cartridge Faucets by ICP-MS [J]. Acta metrologica sinica, 2018, 39 (6): 914-917.
[5]GB 5749—2006生活饮用水卫生标准 [S]. 2006.
[6]杨静. 电感耦合等离子体发射光谱法 (ICP-MS) 与石墨炉原子吸收光谱法测定饮用水中重金属元素的比较 [J]. 中国无机分析化学, 2015, 5 (4):16-19.
Yang J. Comparison of Determination Methods for Heavy Metal Elements in the Drinking Water by ICP-OES and GF-AAS [J]. Chinese Jorunal of Inorganic Analytical Chemistry, 2015, 5 (4):16-19.
[7]袁敏, 武建超, 于劲松, 等. 水中重金属检测方法的研究进展[J]. 应用化工, 2015, 44 (4): 724-728.
Yuan M, Wu J C, Yu J S, et al. Progress on detection methods of heavy metals in water [J]. Applied Chemical Industry, 2015, 44 (4): 724-728.
[8]张鹏妍, 吕凤琴, 马丹丹. 等离子发射光谱仪测定水中重金属的方法研究 [J]. 化学工程与装备, 2019 (4): 257-259.
Zhang P Y, Lv F Q, Ma D D. Determination of heavy metals in water by ICP-AES [J]. Chemical Engineering & Equipment, 2019 (4): 257-259.
[9]王俊平, 马晓星, 方国臻, 等. 电感耦合等离子体质谱法测定饮用水中6种痕量重金属元素 [J]. 光谱学与光谱分析, 2010, 30 (10): 2827-2829.
Wang J P, Ma X X, Fang G Z, et al. Determination of Six Heavy Metals Elements in Drinking Water by Inductively Coupled Plasma Mass Spectrometry [J]. Spectroscopy and Spectral Analysis. 2010, 30 (10): 2827-2829.
[10]王慧, 毛翠. ICP-MS在检测水中重金属元素的应用研究 [J]. 现代盐化工, 2016, 43 (2): 28-29.
Wang H, Mao C. The Plication of ICP-MS in Detecting Heavy Metals in Water Research [J]. Modern Salt and Chemical Industry, 2016, 43 (2): 28-29.
[11]中国环境监测总站. 环境水质监测质量保证手册(第2版)[M]. 北京: 化学工业出版社, 2020: 228.
[12]刘丽, 徐志勇, 王俊超. 称量法配制校准曲线的应用研究 [J]. 化学工程师, 2012, 26 (7): 30-32.
Liu L, Xu Z Y, Wang J C. Research on gravimetry method in preparation of calibration curve [J]. Chemical Engineer, 2012, 26 (7): 30-32.
[13]冯耀基, 黎少映, 兰红军. 称量法配制金属元素标准曲线 [J]. 中国卫生检验杂志, 2018, 28 (16): 1952-1954, 1958.
Feng Y J, Li S Y, Lan H J. Weighing method for preparing standard curve of metal elements [J]. Chin J Health Lab Tec, 2018, 28 (16): 1952-1954, 1958.
[14]张英英, 蒋斌. 称量换算体积代替刻度移液管示值体积在标准曲线制作中的应用 [J]. 浙江预防医学, 2007 (5): 97-98.
Zhang Y Y, Jiang B. Application of weighing conversion volume instead of indicating volume of graduated pipette in making standard curve [J]. Zhejiang Prev Med, 2007 (5): 97-98.
[15]CNAS-CL01-G003:2019测量不确定度的要求 [S]. 2019.
[16]马玉婷, 李正. ICP-MS测定生活饮用水中镍含量不确定度的评定 [J]. 检验检疫学刊, 2019, 29 (6): 50-51.
Ma Y T, Li Z. Evaluation of Uncertainty in Determination of Nickel in Drinking Water by ICP-MS [J]. Journal of Inspection and Quarantine, 2019, 29 (6): 50-51.
[17]陈佩利, 吴电, 郑建伦, 等. ICP-MS法测定水中铊的不确定度探讨 [J]. 资源节约与环保, 2019 (5): 49.
Chen P L, Wu D, Zheng J L, et al. Discussion on uncertainty of determination of thallium in water by ICP-MS [J]. Resources Economization & Environmental Protection, 2019 (5): 49.
[18]孙浩洋, 蒋丽婷, 曾恒. ICP-MS法测定地表水中砷、 镉元素总量的不确定度评定 [J]. 广东化工, 2019, 46 (7): 225-226.
Sun H Y, Jiang L T, Zeng H. Evaluation of Uncertainty in the Determination of Arsenic and Cadmium in Surface Water by ICP-MS [J]. Guangdong Chemical Industry, 2019, 46 (7): 225-226.
[19]崔晓娇, 汪辉, 周鹏, 等. 电感耦合等离子体质谱法同时测定化妆品中铅、 镉、 砷的不确定度评定 [J]. 日用化学品科学, 2019, 42 (12): 27-31.
Cui X J, Wang H, Zhou P, et al. Uncertainty evaluation for simultaneous determination of lead, cadmium and arsenic in cosmetics by inductively coupled plasma mass spectrometry [J]. Detergent & Cosmetics, 2019, 42 (12): 27-31.
[20]李建荣, 张学玲, 陈兵兵, 等. 高效液相色谱-电感耦合等离子体质谱法研究标准曲线质量浓度范围对虾油中无机砷测量不确定度评定的影响 [J]. 中国油脂, 2020, 45 (4): 138-144.
Li J R, Zhang X L, Chen B B, et al. Influence of mass concentration range of standard curve on uncertainty of determination of inorganic arsenic in krill oil by HPLC-ICP-MS [J]. China oils and fats, 2020, 45 (4): 138-144.
[21]李德恒, 陆晶芳, 曾金林, 等. 液相色谱串联质谱法测定鸡蛋中利巴韦林及其代谢物总残留的不确定度评定[J]. 计量学报, 2021, 42(9): 1250-1256.
Li D H, Lu J F, Zeng J L, et al.Evaluation of Uncertainty in Determination of Total Residues of Ribavirin and its Metabolites in Eggs by LC-MS/MS [J]. Acta metrologica sinica, 2021, 42(9): 1250-1256.
[22]范菲,黄炯力,安庆, 等. 化妆品中新补骨脂异黄酮、补骨脂二氢黄酮、补骨脂素和异补骨脂素含量的测量不确定度评定[J]. 计量学报, 2021, 42(8): 1094-1100.
Fan F, Huang J L, An Q, et al.Evaluation of Measurement Uncertainty in the Determination of Psoralen, Lsopsoralen, Neobavaisoflavone and Bavachin in Cosmetics[J]. Acta metrologica sinica, 2021, 42(8): 1094-1100.
[23]秦婷,苏庆,邹琴.微波消解ICP-MS法测定化妆品中镉的不确定度评定[J]. 计量技术, 2019(2): 14-17.
Qin T, Su Q, Zou Q. Evaluation of Uncertainty in Determination of Cd in Cosmetics Using Microwave Digestion ICP-MS[J]. Measurement Technology, 2019(2): 14-17.
[24]GB/T5750.6—2006生活饮用水标准检验方法 金属指标 [S]. 2006.
[25]JJF1059.1—2012 测量不确定度评定与表示 [S]. 2012.
[26]张莹, 曾丹. 微波消解-电感耦合等离子体质谱法测定中药饮片中11种重金属元素 [J]. 分析科学学报, 2013, 29 (6): 851-854.
Zhang Y, Zeng D. Determination of Eleven Heavy Metal Elements in Tradition Chinese Drugs Decoction Piece by Microwave Digestion with Inductively Coupled Plasma Mass Spectrometry [J]. Journal of Analytical Science,2013, 29 (6): 851-854. |
|
|
|