Abstract  In the process of thermocouple calibration, there are some problems such as temperature control lag, long constant temperature time, electric leakage and furnace tube bending caused by using the traditional thermostatic block for calibration furnace. Therefore, a calibration furnace with multiple calorifiers which can meet the requirements of relevant specifications without the temperature uniformity of the thermostatic block has been developed to improve the calibration efficiency. Firstly, according to JJF 1184-2007 Testing Specifications for Temperature Uniformity in Thermocouple Calibration Furnaces, the temperature uniformity of the traditional calibration furnace with single calorifier equipped with the thermostatic block and the calibration furnace with multiple calorifiers without the thermostatic block are tested respectively. Secondly, the two kinds of temperature uniformity are compared and verified by thermocouple indication error test. The results show that in the temperature range of 400~1000℃, the calibration furnace with multiple calorifiers without the thermostatic block is superior to the traditional calibration furnace with single calorifier equipped with the thermostatic block in the axial temperature uniformity, radial temperature uniformity, thermocouple indication error and other tests.
Key wordsmetrology      thermocouple calibration furnace      thermostatic block      multiple calorifier      temperature uniformity     
Received: 20 January 2022      Published: 23 February 2022
PACS:  TB942  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
LIU Hong-yan
ZHANG Shuai-xing
XU Zhen-zhen
ZHANG Kai-xing
ZHANG Jun
Cite this article:   
LIU Hong-yan,ZHANG Shuai-xing,XU Zhen-zhen, et al. Research on Temperature Uniformity of the Calibration Furnace with Multiple Calorifiers[J]. Acta Metrologica Sinica, 2022, 43(2): 228-234.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2022.02.15     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2022/V43/I2/228
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech