The Development and Evaluation of the ZrC-C Peritectic Point |
MENG Su1,2, LIU Xu-dong2, CAI Jing1, DONG Lei1 |
1. Changcheng Institute of Metrology & Measurement of AVIC, Beijing 100095, China
2. Beijing University of Technology, Beijing 100022, China |
|
|
Abstract The ZrC-C peritectic fixed point has a very high nominal phase transition temperature (2882℃), which is higher than the upper limit of most high-temperature heating furnaces. By improving the self-designed HT271 heating furnace, the upper limit of its working temperature was increased to above 2900℃, which met the requirements of the ZrC-C peritectic fixed point experiments. ZrC powder and C powder were used to configure the mixed powder, and the filling and realizing experiments of the ZrC-C peritectic fixed point were carried out, two sets of realizing cycle data were obtained. The result of the first cycle is better: the inflection point temperature is 2882.298℃; the inflection point uncertainty is 26.3mK. It has been verified that at a temperature above 2900℃, the improved HT271 heating furnace can be used for about 30 minutes stably. In order to extend the stable use time of the HT271 furnace at extremely high temperature, the next improvement plan is proposed.
|
Received: 04 August 2020
Published: 06 January 2022
|
|
|
|
|
[1] Celsius. International Temperature Scale of 1990[J]. Ibid, 1990, 27(1): 3-10.
[2] 孟苏, 蔡静, 董磊. Co-C共晶点研制及评价[J]. 计量学报, 2019, 40(1): 8-12.
Meng S, Cai J, Dong L. The development and evaluation of the Co-C eutectic point[J]. Acta Metrologica Sinica, 2019, 40(1): 8-12.
[3] 王铁军, 柏成玉, 原遵东, 等. 高温共晶固定点的建立与复现[J]. 计量学报, 2007, 28(z1): 23-27.
Wang T J, Bai C Y, Yuan Z D, et al. Establishment and reappearance of high temperature eutectic fixed point[J]. Acta Metrologica Sinica, 2007, 28(z1): 23-27.
[4] 王建华, 肖常志, 董伟, 等. Co-C共晶高温固定点灌注研究[J]. 计量学报, 2011, 32(z1): 58-61.
Wang J H, Xiao C Z, Dong W, et al. Study on Co-C eutectic high temperature fixed point filling[J]. Acta Metrologica Sinica, 2011, 32(z1): 58-61.
[5] 卢小丰, 原遵东, 王景辉, 等. 以“固定点-高温计”方式传递961.78℃以上国际温标[J]. 计量学报, 2014,35(3): 193-197.
Lu X F, Yuan Z D, Wang J H, et al. Disseminating the International Temperature Scale above 961.78℃ in the “fixed point-pyrometer” method[J]. Acta Metrologica Sinica, 2014,35(3): 193-197.
[6] Sapritsky V I, Khlevnoy B B, Khromchenko V B, et al. High Temperature Fixed-Point Blackbodies Based on Metal-Carbon Eutectics for Precision Measurements in Radiometry, Photometry and Radiation Thermometry[C]// AIP Conference Proceedings. 2003, 684(1): 273-278.
[7] Khlevnoy B B, Grigoryeva I A. Long-Term Stability of WC-C Peritectic Fixed Point[J]. International Journal of Thermophysics, 2015, 36(2-3): 367-373.
[8] Sakharov M K , Khlevnoy B B , Sapritsky V I , et al. Development and investigation of high-temperature fixed point based on TiC-C eutectic[C]// TEMPMEKO 2004. Zagreb, Croatia, 2004: 319-324.
[9] Hartmann J , Anhalt K , Sperfeld P , et al. Thermodynamic temperature measurements of the melting curves of Re-C, TiC-C and ZrC-C eutectics irradiance mode fixed-point cells[C]// TEMPMEKO 2004. Zagreb, Croatia, 2004: 189-194.
[10] Dong W, Lowe D H, Lu X F, et al. Bilateral ITS-90 comparison at WC-C peritectic fixed point between NIM and NPL[C]// Aip Conference Proceedings. 2013, 1552(1): 786-790.
[11] 董伟, 肖常志, 王铁军, 等. Re-C共晶高温固定点的研制与评价[J]. 计量学报, 2011, 32(z1): 66-69.
Dong W, Xiao C Z, Wang T J, et al. Development and evaluation of the Re-C eutectic high temperature fixed point[J]. Acta Metrologica Sinica, 2011, 32(z1): 66-69.
[12] Khlevnoy B B, Sapritsky V I, Ogarev S A, et al. Development of fixed points above 2700 K based on M-C and MC-C eutectics at VNIIOFI for radiation thermometry and radiometry[C]// TEMPMEKO 2004. Zagreb, Croatia, 2004: 203-208.
[13] 王立平, 何敏. 锆的燃烧与防护[J]. 钛工业进展, 2012, 29(3): 41-43.
Wang L P, He M. Burning and protection of zirconium[J]. Titanium Industry Progress,2012,29(3):41-43.
[14] 李峡. 锆粉热自燃特性的实验研究[J]. 今日科苑, 2010(16): 33-34.
[15] 董伟. 金属碳共晶及包晶高温固定点研究[D]. 北京:清华大学, 2012.