Acta Metrologica Sinica  2021, Vol. 42 Issue (9): 1142-1148    DOI: 10.3969/j.issn.1000-1158.2021.09.04
Current Issue | Archive | Adv Search |
Error Analysis Methodology for Indoor Baseline Field Based on Optical Path Folding
CAI Qing-mei1,ZHAO Mei-rong1,LIU Hong-guang2,ZHENG Ye-long1,ZHANG Han-li1,SONG Le1
1. Precision Instruments and Optoelectronic Engineering College, Tianjin University, Tianjin 300072, China
2. Tianjin Institute of Metrological Supervision and Testing, Tianjin 300192, China
Download: PDF (1648 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  In order to effectively carry out indoor verification of long-distance photoelectric distance measuring instruments, an indoor virtual baseline field was built based on the principle of folding optical path with a group of plane mirrors. The measurement error of the baseline system was analyzed. Considering the adjustment accuracy of various errors, the analysis results were applied to the actual optical path adjustment process. Through the analysis, the errors which have more significant effect on the baseline length were obtained, and they were controlled and adjusted to improve the adjustment accuracy of the parallelism of the measuring optical path. Finally, a dual frequency laser interferometer was used to provide reference length value to carry out the verification experiment. The experimental results show that double optical path multiplication can be achieved by optical path folding method, and the baseline system has high accuracy and can be used for continuous measurement, effectively solving the technical problems of low detection efficiency and poor repeatability in the process of indoor baseline establishment.
Key wordsmetrology      large size measurement      optical path folding      indoor baseline field      dual frequency laser interferometer      plane mirror      error analysis     
Received: 12 June 2020      Published: 24 September 2021
PACS:  TB921  
Fund:;Tianjin Natural Science Foundation
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
CAI Qing-mei
ZHAO Mei-rong
LIU Hong-guang
ZHENG Ye-long
ZHANG Han-li
SONG Le
Cite this article:   
CAI Qing-mei,ZHAO Mei-rong,LIU Hong-guang, et al. Error Analysis Methodology for Indoor Baseline Field Based on Optical Path Folding[J]. Acta Metrologica Sinica, 2021, 42(9): 1142-1148.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2021.09.04     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2021/V42/I9/1142
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech