Selection and Application of Calibration Parameter Optimization for Traction Measurement System with Large Reflective Load
ZHANG Li-fei,DU Jing,WANG Yi-bang,LUAN Peng,WU Ai-hua,LIANG Fa-guo
The 13th Research Institute of China Electronics Technology Group Corporation, Shijiazhuang, Hebei 050051, China
Download: PDF (2613 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Compared with traditional load-pull measurement systems, the active hybrid load-pull measurement system can achieve a larger load impedance adjustment range for microwave power amplifier device testing, which has become a popular measurement solution.For the verification of active hybrid load-pull measurement system, the transducer gain is generally selected as the optimization verification parameter of the load traction measurement system.By comparing the deviation between the theoretical value and the measured value of the power gain and the transducer gain, it is observed that under large reflection conditions, the power gain is more sensitive for the residual error after system calibration, and the effect of optimizing and improving the system accuracy is better.Finally, it is verified by the application experiment of power optimization, it is observed that when the load reflection coefficient reaches 0.9, the transducer gain changes 0.4dB, whereas the power gain changes 0.8dB.Therefore, the effect of selecting the power gain as a large reflection optimization calibration parameter is more obvious.However, under a small reflection coefficient, the transducer gain can be selected as the verification parameter of the load traction measurement system.
Key wordsmetrology      load-pull      power gain      microwave power amplifier device      transducer gain     
Received: 25 February 2020      Published: 15 July 2021
PACS:  TB973  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
ZHANG Li-fei
DU Jing
WANG Yi-bang
LUAN Peng
WU Ai-hua
LIANG Fa-guo
Cite this article:   
ZHANG Li-fei,DU Jing,WANG Yi-bang, et al. Selection and Application of Calibration Parameter Optimization for Traction Measurement System with Large Reflective Load[J]. Acta Metrologica Sinica, 2021, 42(7): 944-949.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2021.07.17     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2021/V42/I7/944
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech