|
|
Study on LED Total Spectral Radiant Flux Measurement Technology |
LIU Hui1,ZHAO Wei-qiang1,LIU Jian1,LI Yi2,ZHAO Hai-su1 |
1.National Institute of Metrology, Beijing 100029, China;
2.Shaanxi Institute of Metrology Science, Xi′an, Shaanxi 710065, China |
|
|
Abstract The theory and method of measuring total radiant flux and total spectral radiant flux is described. The components and character of a goniospectroradiometer had been introduced. Three kind of light sources have been measured, the measurement uncertainty is 1.6%~3.6%(k=2). Luminous flux calculated by the spectra radiant flux comparison with NIM′s photometric based luminous flux scale shows that agreement is within 0.9%, well within the combined measurement uncertainty.
|
|
|
|
|
[1]Ohno Y, Zong Y. NIST Facility for Total Spectral Radiant Flux Calibration[C]// Symposium of Metrologia. CENAM, Mexico : BIPM,2004,1-6.
[2]Zong Y, Ohno Y. Realization of the NIST Total Spectral Radiant Flux Scale[C] // Proceedings of 26th Session of the CIE. Beijing China: CIE, 2007, 179-182.
[3]Ohno Y. Realization of NIST 1995 Luminous Flux Scale using Integrating Sphere Method[ J].IES, 1996,25(1):13-22.
[4]Shaw M, Goodman T. Array-based goniospectroradiometer for measurement of spectral radiant intensity and spectral total flux of light sources[J]. Applied Optics, 2008, 47(14), 2637-2647.
[5]吴继宗,叶关荣.光辐射测量[M]北京:机械工业出版社,1992,179-180.
[6]刘慧,杨臣铸.光度测量技术[M].北京:中国计量出版社,2011,17-18.
[7] Zong Y, Brown S W, Johnson B C, et al. Simple spectral stray light correction method for array spectroradiometers [J].Appl Opt,2006, 45(6):1111-1119. |
|
|
|