[1]段小娟, 吴金杰, 杨元第.程序模拟低能射线光管参数对射线能谱的影响[J].计量学报, 2011, 32(Z1):51-53.
Duan X J, Wu J J, Yang Y D.The Effect of X-rays Tube Parameters Simulated by EGSnrc on Low-energy Spectrum[J]. Acta Metrologica Sinica, 2011, 32(Z1):51-53.
[2]李德红, 郭彬, 黄建微, 等.诊断X射线辐射质的模拟与测量研究[J].中华放射医学与防护杂志, 2017, 37(8):614-617.
Li D H, Guo B, Huang J W, et al.Study on simulation and measurement of diagnostic X-ray radiation qualities[J].Chin J Radiol Med Prot, 2017, 37(8):614-617.
[3]葛双,吴金杰,邱小平,等.工业钼靶射线光机能谱的蒙特卡罗模拟[J].计量学报, 2015, 36(6):647-651.
Ge S, Wu J J, Qiu X P, et al. Monte Carlo Simulation for X-ray Spectrum on Industrial Molybdenum Target Units[J]. Acta Metrologica Sinica, 2015, 36(6):647-651.
[4]徐阳,高飞,肖雪夫,等.过滤射线参考辐射场特性的蒙特卡罗模拟研究及实验验证[J].原子能科学技术, 2017, 51(9):1691-1697.
Xu Y, Gao F, Xiao X F,et al.Study on Characteristic of Filtered X Ray Reference Radiation Field with Monte Carlo Method and Experimental Verification[J].Atomic Energy Science and Technology, 2017, 51(9):1691-1697.
[5]项安, 梁鲁, 陈瑞焘.射线管足跟效应的蒙特卡罗模拟与分析[J].核技术, 2016, 39(6):060202-1-060202-5.
Xiang A, Liang L, Chen R T. Monte Carlo simulation and analysis of X-ray tube’s heel effect[J]. Nuclear Techniques, 2016, 39(6):060202-1-060202-5.
[6]高翔,石丽婉,傅丽蓉,等.基于JJG(闽)1086-2018放射治疗CT模拟定位机X射线辐射源的质控分析[J].计量学报, 2020, 41(6): 743-747.
Gao X,Shi L W,Fu L R, et al. Study on the Quality Control for Computed-tomography Simulators Based on JJG1086-2018[J]. Acta Metrologica Sinica, 2020, 41(6): 743-747.
[7]IEC 61267-2005 Medical diagnostic X-ray Equipment-Radiation conditions for use in the determination of characteristics [S].
[8]Rosado P H G, Squair P L, Nogueira M S, et al. Determination of the mean energy for attenuated and unattenuated IEC diagnostic X-ray beams[C]// International Nuclear Atlantic Conference. Santos,Brazil, 2007.
[9]Gavin G P. Calculation of x-ray spectra emerging from an x-ray tube. Part II.X-ray production and filtration in x-ray targets[J].Med phys, 2007,34(6):2176-2185.
[10]Kawrakow I, Mainegra-Hing E, Rogers D W O, et al. The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport:NRCC Report PIRS-701[R]. National Research Council of Canada, 2015.
[11]Rogers D W O, Walters B, Kawrakow I. BEAMnrc user’s manual :NRCC Report PIRS-0509(A)[R]. National Research Council of Canada, 2015.
[12]MaC M, Rogers D W O. BEAMDP User’s Manual:NRCC Report PIRS-0509(C)[R]. National Research Council of Canada, 2015.
[13]Cranley K, Gilmore B J, Fogarty G W A, et al. Catalogue of Diagnostic X-ray Spectra and Other Data:IPEM Report 78 [R]. The Institution of Physics and Engineering in Medicine and Biology, 1997. |