Calibration Method for Optical Measurement of Ultra-Micro Liquid Volume |
ZHONG Jia-dong1,2,SUN Bin1,ZHAO Yu-xiao1,MA Xin-yu1,2,ZHANG Jing-yue2 |
1.China Jiliang University, Hangzhou, Zhejiang 310018, China
2.National Institute of Metrology, Beijing 100029, China |
|
|
Abstract Static weighing method is commonly used in laboratory to measure the volume of micro-liquid,The accuracy of this method is 2.18% and the repeatability is 1.85% for the volume of 1μL. however, it can not be carried out outside the laboratory. The accuracy and repeatability of the existing optical method for measuring micro-liquid volumetry in 1μL are 6.09% and 1.31%. The mentioned method can realize on-line detection, but its accuracy is not as good as static weighing method. A new method for calibrating the capacity reference standard of this method was found by studying and analyzing the method of optical measurement of micro-liquid capacity. The calibration method combines the static weighing method with the optical measurement method, and takes the static weighing method as a new capacity reference standard instead of the original standard liquid of optical method. The new calibration method extends the reference standard from point to line in principle, and can improve the accuracy of optical measurement at 10μL point to 2.014% and repeatability to 1.30%.
|
Received: 07 December 2018
Published: 13 August 2020
|
|
|
|
|
[1]Thompson D G, Mckenna E O, Pitt A, et al. Microscale mes-oarrys created by dip-pen nanolithography for screening of protein-pro-tein interact[J].Biosensors and Bioe-lectronics, 2011, 26: 4667-4673.
[2]Adler A F, Spridel A T, Christoforou N, et al. High-through-put screening of microscale pitted substrate topographies for enhanced nonviral tranfection efficiency in primary human fibroblarts[J].Biomaterials, 2011, 32(14): 3611-3619.
[3]路士州. 微量生物试剂非接触式分配机理研究[D].哈尔滨: 哈尔滨工业大学, 2011.
[4]Liang D , Steinert C , Bammesberger S , et al. Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range[J]. Measurement Science and Technology, 2013, 24(2):025301.
[5]Kong F W, Zhang Y F, Chen W D, Automatic liquid handling foe life sciecces, a critical review of the current state of theart[C] // International Conference on Robotics and Biomimetics 2009, Bangkok, T-hailand, 2009: 480-486.
[6]张略, 胡泓, 曹勇. 喷射式微流体滴化机理的研究及应用[J].纳米技术与精密工程, 2012, 10(1): 78-82.
Zhang L, Hu H, Cao Y. Droplet generation of microfluidic jetting and its applications[J].Nanotechology and Precision Engineering, 2012,10(1): 78-82.
[7]Merier M, Sit R, Pan W, et al. High-performance binary protein interaction screening in a microfluidic format[J]. Analytical Chemistry, 2012, 84: 9572-9578.
[8]王金涛, 陈超云, 李志昊, 等.超微量液体容积双波长参比测量方法研究[J].计量学报, 2015, 36(3): 256-259.
Wang J T, Chen C Y, Li Z H, et al. Study on Dualwavelength Photometric Method for Ultra Micro Liquid Volume Measurement[J].Acta Metrologica Sinica, 2015, 36(3): 256-259.
[9]Thurow K, Krüger T, Stoll N. An Optical Approach for the Determination of Droplet Volumes in Nano-dispensing[J].J Autom Methods Manag Chem, 2009, (11): 198732-1-10.
[10]Ernst A, Streule W, Schmitt N, et al. A capacitive sensor for non-contact nanoliter droplet detection[J].Sensors and Actuators: A Physical, 2009, 153(1): 57-63.
[11]Liang D, Zhang J, Thanikhatla G M, et al. Liquid volume measurement method for the picoliter to nanoliter volume range based on quartz crystal microbalance technology[J].Measurement Science and Technology, 2014, 25(9): 095302.
[12]徐丹阳, 杜春年. 基于面阵CCD的高灵敏度微型光谱仪的设计与实现[J].光电工程, 2018, 45(11): 180152-10-11.
Xu D Y, Du C N. Design and Implementation of High Sensitivity Micro Spectrometer Based on Area Array CCD[J].Opto-Electronic Engineering, 2018, 45(11): 180152-10-11. |
|
|
|