Study on the Equivalence of Water Equivalent Materials to Water under High-energy X-ray |
WANG Zhi-peng1,2,XING Shu-ming1,WANG Kun2,JIN Sun-jun2,FAN Fu-you2,LIU Fu-bin2 |
1. School of Mechanical Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China
2. National Institute of Metrology, Beijing 100029, China |
|
|
Abstract The problems in the calibration of accelerator using water equivalent materials were described. Three commonly used water equivalent materials were compared to water phantom in measurements of absorbed dose to water. Two Farmer-type cylindrical chamber, PTW 30013 and IBA FC65-G, were used in measurements. The calibration factors of absolute dose between water phantom and water equivalent materials at two depth, 5cm and 10cm, were listed. Through the results of daily stability nearly seven months, the necessity of daily calibration of the accelerator was explained. The dose drift of accelerator and the possible causes were given. By measuring the output factor of twelve radiation fields, the water equivalent material is consistent with water in the relative measurement. Finally, the suggestions and precautions for the water equivalent material in the calibration of high energy X-ray were given.
|
Received: 08 August 2019
Published: 17 February 2020
|
|
|
|
|
[1]Tello V M, Tailor R C, Hanson W F. How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams [J]. Medical Physics, 1995, 22(7): 1177-1189.
[2]Allahverdi M, Nisbet A, Thwaites D I. An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry [J]. Physics in Medicine and Biology, 1999, 44(5): 1125-1132.
[3]Liu L, Prasad S C, Bassand D A. Evaluation of two water-equivalent phantom materials for output calibration of photon and electron beams [J]. Medical Dosimetry, 2003, 28(4): 267-269.
[4]Seuntjens J, Olivares M, Evans M, et al. Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols[J]. Medical Physics, 2005, 32(9): 2945-2953.
[5]McEwen M R, Niven D. Characterization of the phantom material Virtual WaterTM in high-energy photon and electron beams [J]. Medical Physics, 2006, 33(4): 876-887.
[6]Hill R, Kuncic Z, Baldock C. The water equivalence of solid phantoms for low energy photon beams [J]. Medical Physics, 2010, 37(8): 4355-4363.
[7]Schoenfeld A A, Harder D, Poppe B, et al. Water equivalent phantom materials for 192Ir brachytherapy [J]. Physics in Medicine and Biology, 2015, 60(24): 9403-9420.
[8]王建华, 王洵, 任江平, 等. 两种固体模体水等效特性的比较研究 [J]. 中华放射肿瘤学杂志, 2011, 20(3): 236-239.
Wang J H, Wang X, Ren J P, et al. Dosimetric characteristics of water equivalent for two solid water phantoms [J]. Chinese Journal of Radiation Oncology, 2011, 20(3): 236-239.
[9]傅益谋, 陈文俊, 吴剑, 等. 用固体水进行加速器吸收剂量的日常QA校准 [J]. 中国医学物理学杂志, 2017, 34(4): 380-383.
Fu Y M, Chen W J, Wu J, et al. Dose calibration in daily quality assessment of linear accelerator with solid water [J]. Chinese Journal of Medical Physics, 2017, 34(4): 380-383.
[10]王志鹏,王坤,金孙均,等. 医用加速器高能光子束水吸收剂量测量及不确定度分析[J]. 计量学报, 2019, 40(6): 1124-1128.
Wang Z P, Wang K, Jin S J, et al.Measurement and Uncertainty Analysis of Absorbed Dose to Water of High-energy Photons in Medical Accelerator[J]. Acta Metrologica Sinica, 2019, 39(6): 1124-1128.
[11]International Atomic Energy Agency. TRS-398 Absorbed Dose Determination in External Beam Radiotherapy[S]. 2000.
[12]李金凯, 孙新臣, 周苏民, 等. 医用加速器光子线射野输出因子的自动化测量 [J]. 中国医疗设备, 2018, 33(1): 93-107.
Li J K, Sun X C, Zhou S M, et al. Automatic measurement of photon beam output factor for medical accelerator [J]. China Medical Devices, 2018, 33(1): 93-107. |
|
|
|