A No-blind Area Detection Method of Detuning in Continuously Tuned AC Filter |
DENG Ya-ping, TONG Xiang-qian, BAO Yang, FENG Ying |
School of Automation and Information Engineering, Xi’an University of Technology, Xi’an, Shannxi 710048, China |
|
|
Abstract The measurement of detuning is a very crucial step in continuously tuned AC filter, and the detection precision can affect the filtering performance and operation stability. To solve the problem of detection dead zone in existing indirectly measurement of AC filter detuning, a new detection method based on the harmonic voltage crossed between the filter reactor and capacitor is proposed. The presented method not only overcomes the detection blind area, but also has advantages of simple implementation. A detuning detection experimental system is developed, and the results show the effectiveness and accuracy of the proposed method for filter detuning.
|
|
|
|
|
[1] Das J C. Passive filters-potentialities and limitations[J].IEEE Transactions on Industry Applications, 2004,40(1):232-241.
[2] Shuai Z,Luo A,Tu C,et al.New control method of injection-type hybrid active power filter [J].IET Power Electronics, 2011,4(9):1051-1057.
[3] Bula D,Pasko M.Hybrid power filter with single tuned passive filter-dynamical properties[C]//2010 International School on Nonsinusoidal Currents and Compensation, Lagow, Poland, 2010.
[4] Nelson David Epp.A self-tuning filter for the mitigation of power system harmonics[D].Edmonton:University of Alberta,2000.
[5] Tian J, Chen Q, Xie B.Series hybrid active power filter based on controllable harmonic impedance[J].IET Power Electronics, 2012, 5(1):142-148.
[6] Corasaniti V F,Barbieri M B,Arnera P L,et al.Hybrid power filter to enhance power quality in a medium-voltage distribution network[J].IEEE Transactions on Industry Electronics,2009,56(8):2885-2893.
[7] Verma V,Singh B.Design and implementation of a current-controlled parallel hybrid power filter [J]. IEEE Transactions on Industry Applications,2009,45(5):1910-1917.
[8] 康明才,于明涛,陈建业,等.基于裂芯式可控电抗器双调谐滤波器研究[J].电力系统自动化,2005,29(15):53-57.
[9] 同向前,伍文俊,任碧莹.电压源换流器在电力系统中的应用[M].北京:机械工业出版,2012.
[10] 武健,何娜,徐殿国.并联混合有源滤波器复合控制策略[J].电力自动化设备,2009,29(3):97-100.
[11] Bradley D A. Tutorial guides in electronics engineerings: Power Electronics[M].London:Chapman Hall Press,1996.
[12] 同向前,周世平,薛钧义.交流调谐滤波器失谐度检测方法的研究[J].仪器仪表学报,2005,26(5):658-660.
[13] 张家生,刘扬.相位检测方法研究[J].仪器仪表学报,2005,26(5):658-660.
[14] 程浩忠,艾芊,张志刚,等.电能质量[M].北京:清华大学出版社,2006.
[15] 邱关源.电路(第5版)[M].北京:高等教育出版社,2006. |
|
|
|