Acta Metrologica Sinica  2023, Vol. 44 Issue (8): 1202-1207    DOI: 10.3969/j.issn.1000-1158.2023.08.08
Current Issue | Archive | Adv Search |
The Method to Measure Small Angle by Two-arm Non-common Path Non-localized Interference of Point Light Source
ZHANG Bao-wu1,CUI Jian-jun2,OUYANG Ye-feng1,CHEN Kai2,FANG Zhen-yuan1
1. College of Metrology and Measurement Engineering,China Jiliang University, Hangzhou, Zhejiang 310018, China
2. National Institute of Metrology, Beijing 100029, China
Download: PDF (566 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  In order to enhance the measurement precision of the small angle, a method to measure small angle by two-arm non-common path non-localized interference of point light source is presented. In the method, the angle measurement system is built by establishing the theoretical model of small angle measurement, and the interference concentric rings are recorded by the CCD without lens and small pixs on the large target surface. The principle of the method is to fit a series of rings and circle center positioning method by multi-ring regression with both dark ring and bright ring. The method can measure the lateral shift of the center of the circle with high precision, and complete the comparison measurement experiment with the laser interference small angle measuring instrument. For the proposed angle system, the results show that the maximum fluctuation of the stability is -2.46″ in the x direction, and -1.92″ in the y direction within three hours; the repeatability had good agreement with the small angle laser interference within ±0.50″ which has a maximum deviation of -0.45″.
Key wordsmetrology      measure small angle      non-localized interference      concentric rings      two-arm non-common path     
Received: 28 January 2023      Published: 22 August 2023
PACS:  TB922  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
ZHANG Bao-wu
CUI Jian-jun
OUYANG Ye-feng
CHEN Kai
FANG Zhen-yuan
Cite this article:   
ZHANG Bao-wu,CUI Jian-jun,OUYANG Ye-feng, et al. The Method to Measure Small Angle by Two-arm Non-common Path Non-localized Interference of Point Light Source[J]. Acta Metrologica Sinica, 2023, 44(8): 1202-1207.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2023.08.08     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2023/V44/I8/1202
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech