Research for the Resistively Loaded Monocone TEM Cell |
JIANG Ting-yong,WANG Xiao-jia,ZHOU Heng,ZHANG Shou-long |
Northwest Institute of Nuclear Technology, Xi’an, Shaanxi 710069, China |
|
|
Abstract A novel resistively loaded monocone with wide bandwidth and low reflectivity was proposed in this paper. To solve the time window caused by limited length, eight non-inductance resistors networks were applied for the distributed impedance end-loading. Reflections occurred from either the end of cone or the edge of the ground plane was reduced significantly and the operational frequency band-width was widen effectively after loading, especially for the low frequency. The result shows that the measured maximum S11 is less than -17dB from DC to 1GHz for the resistively loaded monocone with length of 1.5m, which broken the time window constraints caused by limited cone length and greatly extended the application for pulse E-field calibration. Correspondingly, the calibration range of measuring system is pushed from ultra-short pulse limited by time window to NEMP with more than 20ns pulse width, as well as for the gain and bandwidth measurement of regular antenna.
|
Received: 03 November 2021
Published: 14 November 2022
|
|
|
|
|
[1]Radasky W A, Baum C E, Wik M W. Introduction to the Special Issue on High-Power Electromagnetics and Intentional Electromagnetic Interference [J]. IEEE Transactions on Electromagnetic Compatibility, 2004, 46(3):314-321.
[2]IEEE Std 1309-2015. IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9kHz to 40GHz [S]. IEEE Electromagnetic Compatibility Society, 2015.
[3]Lawton R A, Ondrejka A U. Antenna and the Associated Time Domain Range for the Measurement of Impulse Field U. S[R]. National Bureau of Standards Technical Note 1008, 1978.
[4]Lee J G, Kang J S, Kim J H. Time domain antenna range at KRISS[C]//2008 Conference on Precision Electromagnetic Measurements Digest. Broomfield, USA, 2008.
[5]Sakharov K Y, Mikheev O V, Turkin V A. National Standard of Russian Federation for Reproduction and Transmission of Unit Sizes of Pulse Electric and Magnetic Intensities in Ultrawide Band Range[C]//The 18th High-Power Electromagnetics Conference. Toulouse, France 2012.
[6]董雪鹤. 脉冲电磁场计量技术研究[D]. 北京:北京交通大学, 2019.
[7]杨超, 孟萃, 李鹏辉, 等. 镜面单锥TEM小室电磁场标准装置[J]. 高电压技术, 2016, 42(5), 1476-1482.
Yang C, Meng C, Li P H, et al. Electromagnetic Field Standard Device-monoconical TEM Cell [J]. High Voltage Engineering, 2016, 42(5), 1476-1482.
[8]姜云升, 徐志谦, 孟萃, 等. 瞬态强电磁场传感器时域联合校准研究[J]. 安全与电磁兼容, 2021, 6, 31-35.
Jiang Y S, Xu Z Q, Meng C, et al. Research on a Time-domain Joint Calibration for Transient Intense Electromagnetic Field Sensors [J]. Safety & EMC, 2021, 6, 31-35.
[9]姜云升, 孟萃, 吴平, 等. 瞬态电磁场传感器校准方 法[J]. 现代应用物理, 2019, 10(4):040501.
Jiang Y S, Xu Z Q, Meng C, et al. A Calibration Method for High Power Transient Electromagnetic Field Sensor [J]. Modern Applied Physics, 2019, 10(4), 040501.
[10]燕有杰, 蒋廷勇, 刘小龙, 等. 镜面单锥结构超宽谱短脉冲电场标准装置[J]. 强激光与粒子束, 2012, 24(12), 2873-2876.
Yan Y J, Jiang T Y, Liu X L, et al. Ultra-wideband short-pulse electric-field standard device with mirror monoconical structure [J]. High Power Laser and Particle Beams. 2012, 24(12), 2873-2876.
[11]蒋廷勇, 燕有杰, 刘小龙, 等. 短电磁脉冲标准场装置实验室比对[J]. 计量学报, 2019, 40 (6):1107-1111.
Jiang T Y, Yan Y J, Liu X L, et al. Inter-laboratory Comparisons of Standard Facilities for Short Pulse E-field [J]. Acta Metrologica Sinica, 2019, 40 (6):1107-1111.
[12]刘潇, 吴艳丽, 秦瑶, 等. TEM室法环天线校准系统建立及测量结果不确定度评定[J]. 计量学报, 2021, 42(8):1061-1067.
Liu X W, Wu Y L, Qin Y, et al. The Loop Antenna Calibration System Using the TEM Method and the Uncertainty Estimation for the Measurement Results [J]. Acta Metrologica Sinica, 2021, 42(8):1061-1067.
[13]周峰, 王景伟, 熊宇飞, 等. IEEE STD 1309-2013电场校准标准的公式与计算讨论 [J]. 计量学报, 2017, 38(6):763-764.
Zhou F, Wang J W, Xiong Y F, et al. Discussion on the Equations and Calculations in the E-field Calibration Standard of IEEE STD 1309-2013 [J]. Acta Metrologica Sinica, 2017, 38(6):763-764.
[14]Jiang T Y, Wang X J, Zhou H, et al. Resistively Loaded Monocone for Pulse Electric Field Calibrations [J]. Review of Scientific Instruments, 2019(10):89-92.
[15]王睿. 场强探头校准用同心锥的研制[D]. 南京:东南大学, 2017.
[16]刘星汛, 齐万泉, 黄承祖, 等. 一种用于电场探头校准的同心锥形横电磁波传输室[C]//2019年全国微波毫米波会议. 广州, 2019, 128-130.
Liu X X, Qi W Q, Huang C Z, et al. A Coaxial conical Transverse Electromagnetic Wave Cell for RF Field Probes Calibration[C]//National Conference on Microwave and Millimeter Waves 2019. Guangzhou, China, 2019. |
|
|
|