Acta Metrologica Sinica  2020, Vol. 41 Issue (8): 989-996    DOI: 10.3969/j.issn.1000-1158.2020.08.16
Current Issue | Archive | Adv Search |
R&D and Performance Evaluation of Reflective Sagnac Interferometer-type Fiber Broadband High Current Measuring Instrument
XIE Xiao-jun,ZHU Cai-yi,LI Qing-xian,LI Hua,LUO Ying
Hunan Institute of Metrology, Changsha, Hunan 410014, China
Download: PDF (1800 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  To deal with the difficulties of quantity transfer and on-line high current calibration for large-scale electric welding and electroplating, a prototype of reflective Sagnac fiber-optic current transformer (RS-FOCT), named fiber broadband high current measuring instrument, was developed and proposed. The prototype utilized the techniques including the linear birefringence suppression, the retarder temperature self-compensation, the closed-loop digital signal detection, and meanwhile implemented optimization design like flexible fiber sensing coil. Several key technical features were tested. The test results showed that the measurement accuracy of the developed prototype is superior to ±0.2% under the experimental condition, the scale factor errors under the changes caused by the temperature, vibration and magnetic field variation, are all less than ±0.2%. Frequency response at 1kHz is attenuated by 0.14%, and the -3dB bandwidth is wider than 10kHz. The accuracy reliability and serviceability in high current online calibration of the measuring instrument were verified. The model’s extended uncertainty of measurement error is 0.10%, the accuracy grade of the measuring instrument is in accordance with 0.2 grade.
Key wordsuncertaintymetrology      high current measuring instrument      fiber-optic current transformer      online calibration      scale factor error      uncertainty     
Received: 14 October 2019      Published: 13 August 2020
PACS:  TB971  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
XIE Xiao-jun
ZHU Cai-yi
LI Qing-xian
LI Hua
LUO Ying
Cite this article:   
XIE Xiao-jun,ZHU Cai-yi,LI Qing-xian, et al. R&D and Performance Evaluation of Reflective Sagnac Interferometer-type Fiber Broadband High Current Measuring Instrument[J]. Acta Metrologica Sinica, 2020, 41(8): 989-996.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2020.08.16     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2020/V41/I8/989
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech