Analysis and Uncertainty Evaluation of Capacitance Measurement of Supercapacitors by Constant Current Discharge Method
XU Feng, LI Zhi-wei, FENG Jian
Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China
Download: PDF (586 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Capacitance is one of the main electrical parameters of supercapacitors, and constant current discharge method is recommended to measure the capacitance of supercapacitors in related standards. Influences of the charging and discharge current, the initial terminal voltage of the capacitor were analyzed based on experiments. And uncertainty of the capacitance measurement was evaluated. Results show that the discharge current has a great influence on the measurement, and the capacitance decreases as the discharge current increases. The charging current and initial voltage have a small effect. The expanded uncertainty of capacitance measurement is 2.2% by constant current discharge method with a confidence factor of 2.
Key wordsmetrology      Supercapacitor      capacitance      constant current discharge method      uncertainty     
Received: 25 June 2018     
PACS:  TB971  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
XU Feng
LI Zhi-wei
FENG Jian
Cite this article:   
XU Feng,LI Zhi-wei,FENG Jian. Analysis and Uncertainty Evaluation of Capacitance Measurement of Supercapacitors by Constant Current Discharge Method[J]. Acta Metrologica Sinica, 2020, 41(4): 489-493.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2020.04.016     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2020/V41/I4/489
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech