Abstract  In order to solve the problem of high pulse current calibration from 1 to 100kA, a high pulse current calibration system was established, and the research on high pulse current calibration and traceability technology were carried out. The calibration system consists of a high current pulse generator, a pulse shunt set, an optical fiber current sensor, a Rogowski coil current sensor, a broadband data acquisition system and a measurement software. The calibration system can be used to calibrate the pulsed high current generation/measurement system with pulse amplitude of 1~100kA and duration of 20μs~100ms. The calibration of Rogowski coil sensor, optical fiber current sensor and other measuring instruments can be carried out, and the calibration uncertainty is better than 1%.
Key wordsmetrology      pulse current      pulse shunt      fiber-optic current sensor      Rogowski coil      calibration     
PACS:  TB971  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
WANG Shu-qiang
ZHANG Jun-qi
CUI Shao-ying
WU Duan
Cite this article:   
WANG Shu-qiang,ZHANG Jun-qi,CUI Shao-ying, et al. Pulse High Current Calibration System[J]. Acta Metrologica Sinica, 2020, 41(3): 296-.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2020.03.05     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2020/V41/I3/296
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech