Research on Calibration Method of Standard Diaphragm |
KE Shu-ting1,KE Gang2,WAN Li-fen1,WANG Li3 |
1. Hubei Institute of Metrology and Testing Technology, Wuhan, Hubei 430071, China
2. Hubei Provincial Institute of Medical Device Quality Supervision and inspection,Wuhan, Hubei 430075, China
3. Wuhan Tianhong Environmental Protection Industry Co., Ltd., Wuhan, Hubei 430223, China |
|
|
Abstract In order to achieve the calibration of the standard diaphragm in ambient air monitoring, the calibration process of the standard diaphragm is standardized, including visual inspection, reduced mass, area, mass per unit area, etc.. Put forward the calibration method of the standard diaphragm will calibrate diaphragm with a single or a combination of the n E2 level weights compare get reduced mass on measuring instrument, the measurement area in the image measuring instrument, and then calculate the standard diaphragm mass per unit area, it is used to calibrate the continuous automatic monitoring equipment of ambient air particles and provide a basis for measuring the accuracy of the automatic monitoring of ambient air particles.
|
Received: 23 October 2020
Published: 23 March 2021
|
|
|
|
|
[1]陈仁杰, 陈秉衡, 阚海东. 大气细颗粒物控制对我国城市居民期望寿命的影响[J]. 中国环境科学, 2014, 34(10): 2701-2705.
Chen R J, Chen B H, Kan H D. Impacts of controlling ambient fine particulate pollution on life expectancy among Chinese urban residents[J]. China Environmental Science, 2014, 34(10): 2701-2705.
[2]HJ 618-2011 环境空气PM10和PM2.5的测定重量法[S]. 2011.
[3]国家环境保护总局《空气和废气监测分析方法》编委会. 空气和废气监测分析方法[M]. 第四版增补版. 中国环境出版社, 2003: 247-248.
[4]HJ 655-2013 环境空气颗粒物(PM10和PM2.5)连续自动监测系统安装和验收技术规范[S]. 2013.
[5]HJ1100-2020 环境空气中颗粒物(PM10和PM2.5)β射线法自动监测技术指南[S]. 2020.
[6]吴佳涛, 陈文亮, 张增福. 基于β射线技术测量PM2.5的准确性研究[J]. 安全与环境学报, 2016, 16(2): 338-342.
Wu J T, Chen W L, Zhang Z F. Exploration of PM2.5 measuring accuracy based on β-ray measure technology[J]. Journal of Safety and Environment, 2016, 16(2): 338-342.
[7]潘焕双, 刘宏, 张帅, 等. 多膜片校准方法在β射线法大气颗粒物监测仪中的应用[J]. 安徽科技, 2016(6): 50-52.
Pan H S, Liu H, Zhang S, et al. Application of multi-diaphragm calibration method in β-ray atmospheric particulate monitoring instrument[J]. Anhui Science & Technology, 2016(6): 50-52.
[8]JJG 99-2006 砝码检定规程[J]. 2006. |
|
|
|