|
|
Studies on Ultrasonic Power Measurement of Cylindrically Converging Wave based on Self-reciprocity Technique |
YU Li-li1,SHOU Wen-de2,3 |
1.Department of Navigation Science, Shanghai Maritime University, Shanghai 201306, China
2.Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, China
3.Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China |
|
|
Abstract A self-reciprocity technique is proposed to measure the ultrasonic power for cylindrical converging wave. This study defines the electro-acoustic parameters of cylindrically converging wave,namely,the reciprocity coefficient,transmission current response,and the voltage sensitivity for the free field. Numerical calculations of reflection and diffraction correction coefficients are discussed. Formulas of ultrasonic power for self-reciprocity technique with cylindrical converging wave are derived. Comparison experiments with radiation force balance (RFB) method shows good agreement. Measuring ultrasonic power via the self-reciprocity technique for cylindrical converging waves is found reasonable and feasible.
|
Received: 09 June 2018
Published: 10 June 2019
|
|
|
|
|
[1]Bouchoux G,Owen N R,Chavrier F,et al. Interstitial Thermal Ablation With a Fast Rotating Dual-Mode Transducer[J]. IEEE Trans on UFFC,2010,57(5):1086-1095.
[2]Bouchoux G,Lafon C,Berriet R,et al. Dual-mode ultrasound transducer for image-guided interstitial thermal therapy[J]. Ultrasound in medicine & biology,2008,34(4):607-616.
[3]寿文德.我国超声测量技术和标准化发展的三十年[J].声学技术,2011,30(1):21-26,45.
Shou W D. Thirty years of ultrasonic measurement and standardization in China[J]. Technical acoustics, 2011, 30(1): 21-26,45.
[4]IEC61161 Ed3:2013,Ultrasonics-Power measurement-Radiation force balances and performance requirements [S].2013.
[5]Hekkenberg R T,Beissner K,Zeqiri B, et al. Validated ultrasonic power measurements up to 20W[J]. Ultrasound in medicine & biology,2001,27(3):427-438.
[6]Sutton Y,Shaw A,Zeqiri B. Measurement of ultrasonic power using an acoustically absorbing well[J]. Ultrasound in medicine & biology,2003,29(10):1507-1513.
[7]Shou W D,Yan J Y,Wang H Z,et al. Free-field reciprocity calibration in a conver-gent spherical acoustic wave of a focusing transducer [J]. Chin Phys Lett,2002,19 (8):1131-1136.
[8]Duan S M,Shou W D,He P Z,et al. A novel method to measure acoustic power of focusing transducer with spherical surface based on self-reciprocity theorem[J]. Chin Phys Lett,2005,22(1):146.
[9]Shou W D,Duan S M,He P Z,et al. Calibration of a focusing transducer and miniature hydrophone as well as acoustic power measurement based on free-field reciprocity in a spherically focused wave field[J]. IEEE Trans on UFFC,2006,53 (3):564-570.
[10]王玉莹,何龙标,祝海江,等. 互易法与表面脉冲法校准声发射传感器的一致性探讨[J]. 计量学报, 2017, 38(5):621-625.
Wang Y Y, He L B, Zhu H J, et al. Comparison of Reciprocity and Surface Pulse Methods for AE Sensor Calibration[J]. Acta Metrologica Sinica, 2017, 38(5):621-625.
[11]鲍勃 R J.水下电声测量[M]. 郑士杰,译. 北京:国防工业出版社,1977.
[12]IEC TS 62903 Ed1:2018,Ultrasonics-Measurements of electroacoustical parameters and acoustic output power of spherically curved transducers using the self-reciprocity method [S].2018.
[13]O′neil H T. Theory of focusing radiators[J]. J Acoust Soc Amer,1949,21(5):516-527. |
|
|
|