PDF(2594 KB)
Research on Traceability Methods for the Voltage Divider Ratio of Standard DC High-Voltage Dividers Based on Distributed Synchronous Data Acquisition Technique
LI Rui, WANG Jiafu, ZHANG Di, CAI Jinhui, SHAO Haiming, WANG Kun, LI Chuansheng, WANG Lixin
Acta Metrologica Sinica ›› 2026, Vol. 47 ›› Issue (3) : 449-458.
PDF(2594 KB)
PDF(2594 KB)
Research on Traceability Methods for the Voltage Divider Ratio of Standard DC High-Voltage Dividers Based on Distributed Synchronous Data Acquisition Technique
The measurement of the voltage coefficient of the division ratio of a DC high-voltage divider is a critical step in the metrological traceability of standard DC high-voltage dividers. A division-ratio traceability method based on distributed synchronous data acquisition is proposed, and a dedicated measurement system is developed to realize the proposed approach. Using the above method and system, three ±100 kV DC high-voltage dividers that can be connected in series were used to verify the effectiveness of the new traceability method at -300 kV. The experimental results show that compared with the direct comparison method, the relative error of the new traceability method is no more than 0.006%, with an uncertainty of U rel =3.7×10-4, k=2, and the E n value comparison result of the two methods is 0.15. This system can also be used to monitor the leakage current of the divider during use in a simple and efficient manner. For the ±300 kV series DC high-voltage divider calibrated in the experiment, the difference between the top and bottom currents of the divider at each voltage measurement point is no more than 0.007%.
electrical measurement / DC high-voltage divider / distributed synchronous sampling / leakage current / voltage ratio / metrological traceability
| [1] |
翟少磊, 罗奕, 段怡, 等. 直流分压器暂态温升及冷却特性研究[J]. 高压电器, 2023, 59(3): 140-149.
|
| [2] |
费烨, 王晓琪, 汪本进,等. ±1000 kV特高压直流互感器的选型与研制[J]. 高电压技术, 2010, 36(10): 2380-2387.
|
| [3] |
王奇, 谭炳源, 刘青松, 等. ±800 kV直流分压器校准分析计算模型研究与应用[J]. 高压电器, 2017, 53(12): 163-167.
|
| [4] |
刘方明, 肖凯, 王海燕, 等. 关于表计输入阻抗在直流高压分压器检定校准中的影响分析[J]. 计量学报, 2023, 44(5): 771-776.
|
| [5] |
林艳, 潘洋, 糜坚平. 直流高压标准装置国际近况[J]. 上海计量测试, 2011,38(4): 9-12.
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
李前.高压直流电压计量标准和现场量值传递方法的研究[D].武汉:华中科技大学,2012.
|
| [10] |
刘开培, 李登云, 朱凯, 等. 基于2/1自校准法的1kV直流电压比例标准量值溯源[J]. 高电压技术, 2022, 48(6): 2226-2233.
|
| [11] |
|
| [12] |
雷民, 姜春阳, 李登云, 等. 高电压比例标准装置技术综述 [J]. 高电压技术, 2021, 47(6): 1893-1904.
|
| [13] |
|
| [14] |
唐海涛, 王晓飞, 王家福, 等. 基于云服务的高压直流分压器远程校准系统[J].计量科学与技术, 2022, 66(4): 120-124+73.
|
| [15] |
蔡俊, 陈晓烽, 吴思汉,等. 基于STM32的电机振动信号采集检测系统[J]. 传感器与微系统, 2019, 38(11): 108-110.
|
| [16] |
胡知川. 基于Golang和Android的电力巡检平台智能化研究和实现[D]. 武汉:武汉科技大学, 2017.
|
| [17] |
张煌辉, 林飞鹏, 邵海明, 等. 直流高压电阻分压器泄漏电流测量研究[J]. 计量学报, 2018, 39(1): 83-88.
|
/
| 〈 |
|
〉 |