Absolute Measurement of Radioactive Gas 85Kr Activity Concentration Using a Digitizer |
TUO Fei1,LU Tianxiang2,ZHANG Ming3,ZHOU Qianqian3,GUO Guiyin4,WANG Shuo1 |
1.National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088,China
2.National Center for Occupational Safety and Health, NHC, Beijing 102308,China
3.National Institute of Metrology, Beijing 100029, China
4.Suzhou Nuclear Power Research Institute Co., Ltd, Suzhou, Jiangsu 215004, China |
|
|
Abstract Based on the length compensation method absolute measurement system for gas-filled proportional counters established by the National Institute of Metrology, this study utilizes the DT5730 digital analyzer developed by CAEN to replace multiple traditional analog electronic modules. The digital analyzer is employed to collect, reconstruct, and analyze β signals offline to perform the absolute measurement of the activity concentration of 85Kr radioactive inert gas.The influence of various conditions is experimentally studied, and the absolute measurement results of 85Kr activity concentration are obtained by correcting the proportional counter end effect, the proportional counter wall effect, background, noise, dead time leakage counts, and sub-threshold counts.Under the same threshold, with a main magnification factor of 100 times, gas pressure of 50.5kPa, and operating voltages of 1675V and 1700V, the relative deviations of 85Kr radioactive activity concentration measurements between the digital analyzer and the electronic modules are 0.83% and 0.74%, respectively. The measurement results are consistent within the uncertainty range, proving that the digital analyzer can effectively replace traditional electronic modules for the absolute measurement of the 85Kr activity concentration.
|
Received: 26 September 2023
Published: 30 September 2024
|
|
|
|
|
[2] |
JORDANOV V T, KNOLL G F, HUBER A C, et al. Digital techniques for real-time pulse shaping in radiation measurements [J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, 353(1-3): 261-264.
|
[8] |
中国计量科学研究院. 一种基于β-γ符合的探测系统及方法: CN202210249379. 4[P]. 2022-07-12.
|
[11] |
User Manual UM3148 DT5730/DT5730S 8 Channel 14 Bit 500/250 MS/s Digitizer[EB/OL]. https: //www. caen. it/products/dt5730/.
|
[13] |
α、β流气式正比计数器的标定和使用: GB/T 20131—2006 [S]. 北京: 中国标准出版社, 2006.
|
[5] |
MORISHITA Y, di FULVIO A, CLARKE S D, et al. Organic scintillator-based alpha/beta detector for radiological decontamination [J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019, 935: 207-213.
|
[6] |
KIM C, YEOM J Y, KIM G. Digital n-γ pulse shape discrimination in organic scintillators with a high-speed digitizer [J]. Journal of Radiation Protection and Research, 2019, 44(2): 53-63.
|
[7] |
CHEPURNOV A S, GAVRILENKO O I, KIRSANOV M A, et al. Study of the influence of ADC sampling rate on the efficiency of neutron-gamma discrimination by the pulse shape [J]. Journal of Physics: Conference Series, 2017, 934(1): 012054.
|
|
LIU H R, ZHOU Q Q, LIANG J C, et al. Activity measurement of 55Fe using the liquid scintillation TDCR method [J]. Nucler Techniques, 2023, 46(1): 67-74.
|
[14] |
复旦大学, 清华大学, 北京大学. 原子核物理实验方法[M]. 3版. 北京: 原子能出版社, 1997.
|
[15] |
MORI C, WU Y, AGEMURA T, et al. Evaluation of counting loss and its correction for small pulses in internal counting with proportional counters [J]. Applied Radiation and Isotopes, 1998, 49(9-11): 1107-1111.
|
[16] |
STANGA D, PICOLO J L, COURSOL N, et al. Analytical calculations of counting losses in internal gas proportional counting [J]. Applied Radiation and Isotopes, 2002, 56(1): 231-236.
|
[4] |
MORISHITA Y. Development of a portable alpha-beta-gamma radioactive material continuous air-monitoring system [J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022, 1027: 166258. DOI: 10. 1016/j. nima. 2021. 166258
|
|
LU T X, ZHOU Q Q, ZHANG M, et al. Absolute measurement of surface particle emission rates from α and β plane sources using a digitizer [J]. Chinese Journal of Radiological Health, 2023, 32(1): 1-5.
|
[1] |
PAUSCH G, MOSZYN′SKI M, WOLSKI D, et al. Application of the pulse-shape technique to proton-alpha discrimination in Si-detector arrays [J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 365(1): 176-184.
|
[10] |
WANG Z L, LI Y Q, ZHANG M, et al. Radioactivity Concentration Measurement of 85Kr Using Length-compensated Internal Gas Proportional Counting Method [J]. Atomic Energy Science and Technology, 2019, 53(12): 2465-2470.
|
[3] |
杜成名. 数字化波形采样技术在粒子探测中的应用与研究[D]. 北京: 中国科学院大学, 2016.
|
[9] |
刘皓然, 周倩倩, 梁珺成, 等. 液闪TDCR方法测量55Fe核素活度 [J]. 核技术, 2023, 46(1): 67-74.
|
[12] |
路天翔, 周倩倩, 张明, 等. 利用数字化仪实现α、β平面源表面粒子发射率的绝对测量 [J]. 中国辐射卫生, 2023, 32(1): 1-5.
|
[17] |
WANG Z L, ZHANG M, TUO F, et al. Standardization of krypton-85 and its calibration on HPGe gamma-ray spectrometer [J]. Applied Radiation and Isotopes, 2020,Doi: 10. 1016/j. apradiso. 2020. 109342.
|
|
|
|