Carbon Dioxide Concentration Measurement of Fixed SourceBased on Herriott Absorption Cell |
MA Lu-yao1,MA Ruo-meng1,ZHU Xiao-yi2,LUO Yong-jia3,REN Ge1,2,LIN Hong1,2 |
1. Zhengzhou Institute of Metrology, Henan, Zhengzhou 450001, China
2. National Institute of Metrology, Beijing 100029, China
3. State High-tech Industry Investment Group, Zhengzhou,Henan 450001, China |
|
|
Abstract Accurate carbon emission measurement is an important step to achieve the goal of "carbon peak and carbon neutral". Among all sources of emissions, the emission of carbon dioxide from point sources is a major factor in the greenhouse effect. Therefore, it is important to accurately measure the concentration of carbon dioxide from point sources. Based on the principle of near-infrared molecular absorption spectroscopy combined with multiple reflection direct absorption spectroscopy, an accurate method was established for the measurement of CO2 concentration using 35% CO2/N2mixture.CO2 transitions from (30012)←(00001)R16e of 6359.97cm-1 to (30012)←(00001)R18e of 6361.25cm-1, the spectral line intensity of R18e was calculated.By comparing the absorption areas of 35% CO2/N2mixtures with other CO2/N2 mixtures, concentrations of 15%, 10%, and 5% CO2/N2 mixtures can be obtained. The results show that the theoretical method and experimental results can well characterize the concentration of the gas to be measured, and the uncertainty of measurement is comparable to that of the weighing method based on balance.
|
Received: 16 November 2021
Published: 23 March 2022
|
|
|
|
|
[1]赵国涛, 钱国明, 王盛, 等. “双碳”目标下火电企业绿色低碳转型的对策分析[J]. 华电技术, 2021, 43(10): 11-21.
Zhao G T, Qian G M, Wang S, et al. Countermeasure analysis of green and low-carbon transformation of thermal power enterprises under the goal of “double carbon” [J]. Huadian Technology, 2021, 43 (10): 11-21.
[2]邹冰妍, 林鸿, 张亮, 等. 点排放源中二氧化碳浓度的测量研究[J]. 计量学报, 2019, 40(2): 246-251.
Zou B Y, Lin H, Zhang L, et al. Study on the measurement of carbon dioxide concentration in point emission source [J]. Acta Metrologica Sinica, 2019, 40 (2): 246, 251.
[3]胡鹤鸣, 王池, 张金涛. 城市区域碳排放测量反演研究国际进展[J]. 计量学报, 2017, 38(1): 7-12.
Hu H M, Wang C, Zhang J T. international progress in inversion of urban regional carbon emission measurement [J]. Acta Metrologica Sinica, 2017, 38 (1): 7-12.
[4]Nwaboh J A, Werhahn O, Ortwein P, et al. Laser-spectrometric gas analysis: CO;2-TDLAS at 2μm[J]. Measurement Science and Technology, 2012, 24(1): 015202.
[5]Hummelga Rd C, Bryntse I , Bryzgalov M , et al. Low-cost NDIR based sensor platform for sub-ppm gas detection [J]. Urban Climate, 2015, 14: 342-350.
[6]Zhu X, Yao S, Ren W, et al. TDLAS monitoring of carbon dioxide with temperature compensation in power plant exhausts[J]. Applied Sciences, 2019, 9(3): 442.
[7]吕洪震, 马若梦, 张亮, 等. 基于傅里叶红外光谱仪的高温含水烟气中低浓度一氧化氮精确测量研究[J]. 计量学报, 2021, 42(4): 526-531.
Lü H Z, Ma R M, Zhang L, et al. Study on accurate Measurement of low concentration of nitric oxide in High temperature Aqueous flue Gas based on Fourier transform Infrared Spectrometer [J]. Acta Metrologica Sinica, 2021, 42 (4): 526, 531.
[8]马若梦, 林鸿, 张亮, 等. 基于多次反射直接吸收精确测量二氧化碳浓度的研究[J]. 计量学报, 2020, 41(4): 425-429.
Ma R M, Lin H, Zhang L, et al. Study on accurate measurement of carbon dioxide concentration based on multiple reflection direct absorption [J]. Acta Metrologica Sinica, 2020, 41(4): 425-429.
[9]Liu C, Xu L J, Chen J L, et al. Development of a fan-beam TDLAS-based tomographic sensor for rapid imaging of temperature and gas concentration [J]. Opt Express, 2015, 23(17): 22494-22511.
[10]潘金明, 林鸿, 冯晓娟, 等. CO的第二泛频(3←0)跃迁谱线线形强度测量研究[J]. 计量学报, 2020, 41(12): 1565-1569.
Pan J M, Lin H, Feng X J, et al. Study on the linear intensity measurement of the second overtone (3←0) transition spectrum of CO [J]. Acta Metrologica Sinica, 2020, 41 (12): 1565-1569.
[11]Kassi S, Campargue A. Electric quadrupole and dipole transitions of the first overtone band of HD by CRDS between 1. 45 and 1. 33μm[J]. Journal of Molecular Spectroscopy, 2011, 267(1-2): 36-42.
[12]Lackner M. Tunable diode laser absorption spectroscopy (TDLAS) in the process industries-a review[J]. Reviews in Chemical Engineering, 2007, 23(2): 65-147.
[13]任歌, 张亮, 林鸿, 等. 温室气体和大气污染物排放量监测与计量研究[J]. 计量技术, 2020 (5): 79-84.
Ren G, Zhang L, Lin H, et al. Research on the Monitoring and Measurement of Greenhouse Gas and Air Pollutant Emissions[J]. Measurement Technique,2020 (5): 79-84.
[14]马路遥,林俊,张亮,等. 温室气体浓度监测的光腔衰荡光谱研究进展[J]. 计量学报,2022,43(2):274-280.
Ma L Y, Lin J, Zhang L, et al. Review on the Cavity Ring-down Spectroscopy forGreenhouse Gas Monitoring[J]. Acta Metrologica Sinica, 2022, 43(2):274-280. |
|
|
|