|
|
Real Flow Calibration of Standard Nozzles Under High Pressure Natural Gas |
CHEN Xing-chuan |
Nanjing Measurement Testing Center, West East Gas transmission branch of PetroChina Pipeline Co., Ltd, Nanjing, Jiangsu 210058, China |
|
|
Abstract In order to verify the performance of standard nozzles under the condition of high pressure natural gas, two standard nozzles with different diameters were selected to carry out the real flow calibration test under different pressure conditions. The work standard device of Guangzhou branch of National Petroleum and Natural gas mass flow metering station was used to carry out the test. The experimental results show that the test results of standard nozzles at three different pressure points are consistent, and the test results at each pressure point meet the requirements of GB/T 18603 class A metering system. Meanwhile, the uncertainty evaluation of DN200 caliber standard nozzles was conducted, and the evaluation results also meet the requirements of GB/T 18603 class A metering system. Standard nozzles perform well under high pressure natural gas.
|
|
|
|
|
|
[1]蔡武昌, 孙淮清, 纪纲. 流量测量方法和仪表的选用[M]. 北京: 化学工业出版社, 2001.
[2]杨国芬, 章宦辉, 叶友意, 等. 高压气体涡轮流量计研究[J]. 自动化仪表, 2018, 39(8): 84-88.
Yang G F, Zhang H H, Ye Y Y, et al. Research on High Pressure Gas Turbine Flowmeter[J]. Process Automation Instrumentation, 2018, 39(8): 84-88.
[3]杨友涛,王子钢.涡轮流量计[M]. 北京: 中国质检出版社, 2011: 32-33.
[4]陈松, 黄坤, 马国光, 等. 用于天然气流量计量的超声流量计[J]. 油气储运, 2002, 26(5): 37-40.
Chen S, Huang K, Ma G G, et al. The Ultrasonic Flow Meter Used to Measure Flow Rate of Natural Gas[J]. Oil & Gas Storage and Transportation, 2002, 26(5): 37-40.
[5]Lynnworth L C, Liu Y. Ultrasonic flowmeters: Half-century progress report, 1955—2005[J]. Ultrasonics, 2006, 44(supp-S): e1371-e1378.
[6]Franchini S, Sanz-Andrés A, Cuerva A. Measurement of velocity in rotational flows using ultrasonic anemometry: the flowmeter[J]. Experiments in Fluids, 2007, 42(6): 903-911.
[7]Holden J L, Peters R J W. Practical experiences using ultrasonic flowmeters on high pressure gas[J]. Flow Measurement & Instrumentation, 1991, 2(1): 69-73.
[8]吴金广. 从节能角度看流量计的选择[J]. 能源与节能, 2019, 24(8): 65-66+84.
Wu J G. Selection of Flowmeter from the Angle of Energy Saving[J]. Energy and Energy Conservation, 2019, 24(8): 65-66+84.
[9]国明昌, 丁建林, 邱惠. 高压天然气流量计现场在线实流检定[J]. 计量学报, 2008, 29(5): 411-415.
Guo M C, Ding J L, Qiu H. In-situ Calibration of High Pressure Natural Gas Flowmeters[J]. Acta Metrologica Sinica, 2008, 29(5): 411-415.
[10]丁建林, 国明昌, 邱惠, 等. 高压天然气流量标准装置[J]. 计量学报, 2008, 29(5): 479-483.
Ding J L, Guo M C, Qiu H, et al. High Pressure Natural Gas Flowmeter Calibration Facilities[J]. Acta Metrologica Sinica, 2008, 29(5): 479-483.
[11]张福元, 高军, 王京安. 采用标准喷嘴流量计测量天然气流量探析[J]. 中国计量, 2016, 22(1): 96-100.
Zhang F Y, Gao J, Wang J A. The standard nozzle flowmeter was used to measure the natural gas flow[J]. China Metrology, 2016, 22(1): 96-100.
[12]周国祥, 孙淮清. 用标准喷嘴流量计测量天然气流量及标准的制定[J]. 城市燃气, 2013, 22(8): 19-22.
Zhou G X, SUN H Q. Use standard nozzle flowmeter to measure natural gas flow rate and establish the standard[J]. Gas Technology, 2013, 22(8): 19-22.
[13]GB/T 34166-2017 用标准喷嘴流量计测量天然气流量[S].
[14]GB/T 18603-2014 天然气计量系统技术要求[S].
[15]GB/T 21446-2008 用标准孔板流量计测量天然气流量[S].
[16]ISO 5167-3-2003 用安装在圆形截面管道中的差压装置测量满管流体流量. 第3部分: 喷嘴和文丘里喷嘴[S]. |
|
|
|