Research on Measurement Performance of Ultrasonic Flowmeter Based on Reticulated Acoustic Path Arrangement |
CHEN Hui,YAN Xue-zhi |
Huizhong Instrumentation Co., Ltd., Tangshan, Hebei 063020, China |
|
|
Abstract An ultrasonic flowmeter for liquid based on reticulated acoustic path arrangement is developed. The layout of ultrasonic transducers based on the principle of directivity, and a 16-channel ultrasonic flowmeter formed by 16 transducers in DN100 diameter is realized by using one transducer to transmit the ultrasonic wave and the other two transducer to receive. Through the intrinsic errors test and repeatability test under normal installation condition, the accuracy level of 0.2 is achieved, and the repeatability is less than 0.6‰. In addition, the flow field adaptability and stability of the ultrasonic flowmeter based on reticulated acoustic path arrangement are verified through the intrinsic errors test of indication after the Angle installation and flow disturbance.
|
|
|
|
|
|
[1]Zheng D, Zhao D, Mei J. Improved numerical in-tegration method for flowrate of ultrasonic flowmeter based on Gauss quadrature for non-ideal flow fields[J]. Flow measurement and Instrumentation, 2015,(41): 28-35.
[2]涂晓立, 杨道业, 陈静. 超声波多普勒流量计的设计[J]. 仪器仪表与传感器, 2016,(3): 41-43.
Tu X L, Yang D Y, Chen J. Design of Ultrasonic Doppler Flowmeter[J]. Instrument Technique and Sensor. 2016,(3): 41-43.
[3]于光平, 陈强. 相关法在超声波流量计设计中的应用[J]. 沈阳工业大学学报, 2008, 30(2): 207-211.
Yu G P, Chen Q. Application of correlation method in design of ultrasonic flow meter[J]. Journal of Shenyang University of trchnology, 2008, 30(2): 207-211.
[4]Sutham K K. An Ultrasonic Tomography for Reconstructing the Velocity Profile of Air Flow from Nonuniformly Spaced Projection Data[J]. Trans. of the Society of Instrument and Control Engineers, 1992, 28(11):1274-1281.
[5]Kurniadi D, Trisnobudi A. A Multi-Path Ultrasonic Transit Time Flow Meter Using aTomography Method for Gas Flow Velocity Profile Measurement[J]. Particle & Particle Systems Characterization, 2006,(23):330-338.
[6]Emmanuelle M, Denis K. Methodology for Developing a High-Precision Ultrasound Flow Meter and Fluid Velocity Profile Reconstruction[J]. Ieee transactions on ultrasonics, ferroelectrics, and frequency control, 2008, 55(1): 161-172.
[7]王伯雄, 柳建楠,等, 一种针对管道内流体轴向流场的超声成像方法及设备: 中国, CN103336145A[P]. 2013-06-18.
[8]冯若. 超声手册[M]. 南京: 南京大学出版社, 1999: 255-257.
[9]Yeh T T, Espina P I. An intelligent ultrasonic flowmeter for improved flow measurement and flow calibration facility[C]//IEEE Instrumentation and Measurement Technology Conference. Budapest, Hungary, 2001: 1741-1746.
[10]JJG 1030-2007超声流量计检定规程[S].
[11]GB/T 778. 2-2018饮用冷水水表和热水水表第2部分: 试验方法[S]. |
|
|
|