|
|
Research on X-ray Attenuation Coefficient Measurement Method Based on Radiography |
YU Tuo-xia,XI Qing,YANG Dan |
China Academy of Engineering Physics, Mianyang, Sichuan 621900, China |
|
|
Abstract A method for calculating the attenuation coefficient of X-rays in matter by radiography was proposed. The attenuation coefficient of X-rays with different energies in matter was quickly obtained through simple experiments and calculation. The design experiment found out the relation curve between the blackness of the negative and the thickness of the workpiece, deduced the expression, and obtained the confidence interval of the expression. The X-ray attenuation coefficients of steel stepped test block at 140kV, 130kV and 120kV tube voltages were measured by radiographic method. The standard errors were less than 3%, which proved the reliability of the method. The X-ray radiography method is simple in calculation, convenient in operation and small in error. It is expected to be widely applied to the estimation of X-ray attenuation coefficient in materials.
|
Received: 14 January 2019
Published: 02 November 2020
|
|
|
|
|
[1]Estre N, Eck D, Pettier J-L, et al. High-energy X-ray imaging applied to non destructive characterization of large nuclear waste drums [C]// IEEE. 2013 3rd Int-ernational Conference on Advancements in Nuclear Instru-mentation, Measurement Methods and their Applications (ANIMMA), Marseille, France, 2013.
[2]郭思明, 刘莹, 吴金杰. 乳腺X射线基准装置半值层的测量 [J]. 计量学报, 2018, 39 (3): 410-413.
Guo S M, Liu Y, Wu J J. Half Value Layer Measurement of Mammography X-Ray Standard [J]. Acta Metrologica Sinica, 2018, 39 (3): 410-413.
[3]杨福家. 原子物理学 [M]. 上海: 上海科学技术出版社, 1985.
[4]强天鹏. 射线检测 [M]. 北京: 中国劳动社会保障出版社, 2007.
[5]王同权, 魏晓东, 李宏杰, 等. X射线的衰减和能量沉积计算 [J ]. 原子能科学技术, 2007, 41 (4): 399-403.
Wang T Q, Wei X D, Li H J, et al. Calculation of X-ray Attenuation and Energy Deposition [J]. Atomic Energy Science and Technology, 2007, 41 (4): 399-403.
[6]张小海, 刘二军. 射线照相检测中X射线强度衰减的数值分析 [J ]. 无损检测, 2012, 34 (6): 1-4.
Zhang X H, Liu E J. Numerical Analysis on X-Ray Intensity Attenuation in RadiographicTesting [J]. Non-destructive Testing, 2012, 34 (6): 1-4.
[7]杜海燕, 李凡, 吴金杰, 等. 同步辐射单能X射线空气质量衰减系数的测量 [J]. 计量学报, 2019, 40 (2): 333-336.
Du H Y, Li F, Wu J J, et al. The Measurement of Synchrotron Radiation Single-energy X-ray Massattenua-tion Coefficient of Air[J]. Acta Metrologica Sinica, 2019, 40 (2): 333-336.
[8]冯常春, 周炜. X射线衰减系数与射线管电压的关系初探[J ]. 无损检测, 1997, 19 (1):8-10.
Feng C C, Zhou W. Discussion On Relationship Between X-ray Attenuation Cofficient And Tube Voltage [J]. Non-destructive Testing, 1997, 19 (1): 8-10.
[9]王玉玲, 肖秀友. X射线能量变化对其在炸药中衰减规律的研究 [J ]. 核电子学与探测技术, 2007, 27 (3): 600-602.
Wang Y L, Xiao X Y. Effect of X-ray energy on its fading rule in explosive [J]. Nuclear Electronics and Detection Technology, 2007, 27 (3): 600-602.
[10]李梦石, 吴金杰, 郭思明, 等. 225kV X光机管电压、管电流及固有过滤的研究 [J]. 计量学报, 2018, 39 (Z1): 127-130.
Li M S, Wu J J, Guo S M, et al. Study on 225kV X-ray Tube Voltage, Tube Current and Intrinsic Filtration [J]. Acta Metrologica Sinica, 2018, 39 (Z1): 127-130.
[11]杜继星, 张晓敏, 宁静, 等. 医用诊断X射线的衰减与防护研究 [J]. 军事医学, 2016, 40 (6): 505-507.
Du J X, Zhang X M,Ning J, et al. Attenuation and protection study of medical diagnostic X-rays [J]. Mil Med Sci, 2016, 40 (6): 505-507. |
|
|
|