The Pilot Comparison Calibration of Vector Receivers in the Frequency Range 5 Hz to 10 kHz

CHEN Yi,JIA Guang-hui,FEI Teng,Isaev A E,Matveev A N

Acta Metrologica Sinica ›› 2020, Vol. 41 ›› Issue (10) : 1279-1283.

PDF(1777 KB)
PDF(1777 KB)
Acta Metrologica Sinica ›› 2020, Vol. 41 ›› Issue (10) : 1279-1283. DOI: 10.3969/j.issn.1000-1158.2020.10.16

The Pilot Comparison Calibration of Vector Receivers in the Frequency Range 5 Hz to 10 kHz

  • CHEN Yi1,2,JIA Guang-hui1,FEI Teng1,Isaev A E3,Matveev A N3
Author information +
History +

Abstract

Using three vector receivers VHS56, VHS90 and KPG-10 as reference vector receivers, the comparison calibration of vector receivers in the frequency range 5Hz to 10kHz was performed between HAARI, China and VNIIFTRI, Russia . The sensitivities of X, Y and Z channels of three vector receivers were calibrated by free-field reciprocity calibration facilities and vertical standing wave tube comparison calibration facilities of HAARI and VNIIFTRI. The calibration results of two participants were consonant with each other. There was only one frequency points deviation between calibration results and reference values slightly exceeding the reference expand uncertainties in all 174 calibration frequency points, and the deviations at most frequency points were less than ±0.5dB, which tested and verified the correction and reliability of the calibration results of vector receivers given by both participants international calibration facilities.

Key words

metrology / vector receiver / sensitivity / international comparison calibration

Cite this article

Download Citations
CHEN Yi,JIA Guang-hui,FEI Teng,Isaev A E,Matveev A N. The Pilot Comparison Calibration of Vector Receivers in the Frequency Range 5 Hz to 10 kHz[J]. Acta Metrologica Sinica. 2020, 41(10): 1279-1283 https://doi.org/10.3969/j.issn.1000-1158.2020.10.16

References

[1]杨德森, 洪连进. 矢量水听器原理及应用引论[M]. 北京: 科学出版社, 2009.
[2]陈毅, 袁文俊, 赵涵. 水下电声参数测量[M]. 北京: 兵器工业出版社, 2017.
[3]Bauer B B, Abbagnaro L A, Schumann J. Wide range calibration system for pressure gradient hydrophones[J]. J Acous Soc Am, 1972, 51(2): 1717-1724.
[4]Strasberg M, Schloss F. Calibration of pressure gradient transducers in an oscillating liquid column[J]. J Acous Soc Am, 1973, 54(2): 553.
[5]Gordienko V A, Gordienko E I, Dryndin A V, et al. Absolute pressure calibration of acoustic receivers in a vibrating column of liquid[J]. Acoustical physics, 1994, 40(2): 219-222.
[6]薛耀泉, 唐长寿. 压力梯度水听器灵敏度校准[J]. 声学与电子工程, 1996, (3): 22-26.
Xue Y Q, Tang C S. The sensitivity calibration of pressure gradient hydrophone [J]. Acoustics and Electronics Engineering, 1996, (3): 22-26.
[7]莫喜平, 王文芝, 郑士杰. 偶极子接收换能器驻波场校准系统的研究[J]. 应用声学, 1998, 17(6): 158-160.
Mo X P, Wang W Z, Zheng S J. A standing wave calibration system for dipole hydrophones [J]. Applied Acoustics, 1998, 17(6): 158-160.
[8]费腾. 矢量水听器校准装置[C]//2005年全国水声学学术会议: 289-291.
[9]贾广慧. 矢量水听器自由场校准方法研究[D]. 杭州: 杭州应用声学研究所, 2016.
[10]Isaev A E, Matveev A N, Nekrich G S,  et al. Results of the Coomet 646/Ru/14 Pilot Comparison of National Standards of the Unit of Sound Oscillation Velocity of  Water Particles[J].  Measurement Techniques, 2019, 62: 651-658.
[11]Chen Y, Isaev A E, Jia G H, et al. Calibration methods of vector receivers in the frequency range 5 Hz to 10 kHz and their comparison verifications [C]//Proceedings of the 5th International Conference and Exhibition on Underwater Acoustics, Crete, Greece, 2019.
[12]IEC 60565: 2006, Underwater acoustics-Hydrophones-Calibration of hydrophones in the frequency range 0. 01 Hz to 1MHz [S]. International Electrotechnical Commission, Geneva, Switzerland.
[13]Jia G H, Chen Y, Ping Z H, et al. Low frequency absolute calibration of complex sensitivity of vector receiver in free-field [C]//MATEC Web of Conferences 283(FCAC2018), 05003(2019).
[14]Isaev A E, Matveev A N, Nekrich G S. Complex calibration of a pressure gradient receiver using the reciprocity method procedure [J]. Acoustical Physics, 2014, 60(1): 45-51.
[15]Isaev A E, Matveev A N. Two approaches to hydrophone free-field calibration at continuous radiation in non-anechoic water tank[J]. Measurement Techniques, 2008, 51(12): 1329-1336.
[16]Cox M G. The evaluation of key comparison data: determining the largest consistent subset[J]. Metrologia, 2005, 39(4): 589-595.
PDF(1777 KB)

Accesses

Citation

Detail

Sections
Recommended

/