|
|
A Coaxial-to-waveguide Adaptor Calibration Method using an Adjustable Shorter with Unspecified Phases |
WU Chang-ying,XIE Chun-jian,WEI Gao,XU Jia-dong |
School of Electronic Information, Northwestern Polytechnical University Chang'an Campus, Xian, Shaanxi 710129, China |
|
|
Abstract A technique is described to remove the coaxial-to-waveguide adaptor errors when the reflection coefficient of waveguide device is measured by vector network analyzer.This technique utilizes a matched load and an adjustable shorter with several unspecified phases.And one of the shorted planes is used as reference plane.It is shown that the technique is resistant to the error of the adjustable shorter position and is easy to implement.The efficiency of this technique is verified by measurement data in X band.
|
|
|
|
|
|
[1]Huang C C, Lin H C. A novel calibration algorithm with unknown line-series-shunt standards for broadband S-parameter measurement[J].IEEE Transactions on Instrumentation and Measurement,2008,57(5):891-895.
[2]Juan Monzó-Cabrera,Juan L,Pedre-Molina,et al.A novel design of a robust ten-port microwave reflectometer with autonomous calibration by using neural networks[J].IEEE Transactions on Microwave Theory and Techniques,2008,56(4):946-961.
[3]Liu Z Y,Weikle R M.A reflectometer calibration method resistant to waveguide flange misalignment[J].IEEE Transactions on Microwave Theory and Techniques,2006,54(6):2447-2452.
[4]Qiao L,Yeo S P.Correction of adaptor errors in reflection-coefficient measurements of waveguide devices[C]// ICCS '94 Conference Proceedings,Singapore,1994.
[5]Stevens N,Matens L.Sensitivity study on the measurement of the reflection coefficient in a short-circuited rectangular waveguide filled with a liquid[C]//Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference,Bundapest,Hungary, 2001. |
|
|
|