2025年05月28日 星期三 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2011, Vol. 32 Issue (z1): 30-32    DOI: 10.3969/j.issn.1000-1158.2011.z1.08
  本期目录 | 过刊浏览 | 高级检索 |
用于职业个人监测的CR39中子个人剂量计
曹磊1,邓君1,张贵英2,刘运宏1,郭文1,胡爱英1
1. 中国疾病预防控制中心辐射防护与核安全医学所, 北京 100088
2. 中国原子能科学研究院, 北京 102413
CR39 Fast/Thermal Neutron Personal Dosimeter Used in IM for Occuptional External Exposure
CAO Lei1,DENG Jun1,ZHANG Gui-ying2,LIU Yun-hong1,GUO Wen1,HU Ai-ying1
1. National Institute for Radiological Protection  Chinese Center for Disease Control and Prevention,Beijing 100088, China
2. China Institute of Atomic Energy, Beijing 102413, China
全文: PDF (420 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 中子个人剂量监测是外照射职业监测的重要组成部分。根据CR39中子探测原理与剂量计的结构,对CR39中子个人剂量计的能量响应、角度响应以及对镅铍中子源产生的中子注量响应等进行性能实验。结果表明中子注量灵敏度与中子能量和入射角有较强的中子依赖性,入射中子的临界角约为64°,该批次CR39对241Am-Be源的中子注量灵敏度约为2.24×10-4tracks/(n·cm2)。在此基础上,采用聚乙烯和BN结构作为CR39探测器的前置径迹转换体,利用10B(n,α)7Li反应产生的α粒子径迹提高了CR39的外赋响应能力,MC模拟和241Am-Be源实验说明,该CR39中子个人剂量计实现了快/热中子的分群测量。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
曹磊
邓君
张贵英
刘运宏
郭文
胡爱英
关键词 计量学CR39中子个人剂量计中子个人剂量监测性能实验    
Abstract:Neutron personal dose monitoring is an important part of external monitoring for occupational exposure. From neutron detecting theory of CR39 and dosimeter structure points of view, experiments regarding energy response and angle response as well as dose equivalent response of CR39 neutron personal dosimeter against neutron emitted by Am-Be were carried out. Results show that neutron flux sensitivity strongly depends on the energy and incident angle of neutron. The critical angle of 64° for incident neutron and neutron dose equivalent sensitivity of about 2.14×10-4tracks/(n·cm2) are obtained. The externally-assigned response of CR39 detector is improved through increasing the track density by using the α particle induced by the reaction of 10B(n,α)7Li with the BN as pre-recoil layer, and the increase is vilified by using both Monte-Carlo simulation and experiment exposed by standard neutron source. The personal dosimeter have the ability to distinguish fast/thermol neutrons.
Key wordsMetrology    CR39 neutron personal dosimeter    Neutron personal dose monitoring    Performance test
    
PACS:  TB98  
作者简介: 曹磊(1975-),甘肃兰州人,中国疾病预防控制中心辐射防护与核安全医学所助理研究员,硕士,研究方向为辐射防护与辐射剂量学。caolnirp@163.com
引用本文:   
曹磊,邓君,张贵英,刘运宏,郭文,胡爱英. 用于职业个人监测的CR39中子个人剂量计[J]. 计量学报, 2011, 32(z1): 30-32.
CAO Lei,DENG Jun,ZHANG Gui-ying,LIU Yun-hong,GUO Wen,HU Ai-ying. CR39 Fast/Thermal Neutron Personal Dosimeter Used in IM for Occuptional External Exposure. Acta Metrologica Sinica, 2011, 32(z1): 30-32.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2011.z1.08     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2011/V32/Iz1/30
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn