Abstract:The electrostatic sensor inserted into pipes is successfully applied for measuring the parameters of the gas-solid two phase flow and ensuring the safety during the gas-solid two phase flow convey.Through establishing the mathematical model of the probe, the inserted depths,spatial filter characteristics and the spatial sensitivity characteristics of the inserted probe are discussed. The situation which the particles position effect on the induced charges of the probe, and the relation between the inserted depth of probe and the signal amplitude measured are obtained. For the continuous flow of solid particles inserted probe,the optimum inserted depth is 1/2 of the pipe diameter and the probe has low-pass filter characteristic.The expression about the solid particle velocity and the measured signal cut-off frequency is obtained during deducing spatial filter characteristic of the probe with probe mathematics model.The measured results confirm the spatial filter characteristic and spatial sensitivity characteristic of the probe.
阚哲,邵富群,李成志,李庆华. 插入式静电传感器特性研究[J]. 计量学报, 2011, 32(2): 141-146.
KAN Zhe,SHAO Fu-qun,LI Cheng-zhi,LI Qing-hua. Study on the Characteristics of Electrostatic Sensor Inserted into Pipes. Acta Metrologica Sinica, 2011, 32(2): 141-146.
[1]Yan Y,Byrne B,Woodhead S R,et al. Velocity measurement of pneumatically conveyed solids using electrodynamic sensors[J]. Measurement Science and Technology,1995,6(3):515-537.
[2]Xu C,Wang S. Velocity measurement of pneumatically conveyed solid particles using an electrostatic[J]. Meas Sci Technol,2008,19(12):1-9.
[3]Gajewski J B. Monitoring electrostatic flow noise for mass flow and mean velocity measurement in pneumatic transport[J]. Journal of Electrostatics, 1996,37(4):261-276.
[4]Yan Y. Mass flow measurement of bulk solids in pneumatic pipelines[J]. Measurement Science and Technology,1996,7(9):1687-1706.
[5]Gajewski J B. Continuous non-contact measurement of electric charges of solid particles in pipes of pneumatic transport.Ⅰ. Physical and mathematical models of a method[C]//IEEE/ISA Annual Meeting,San Diego,CA,1989.
[6]Yan Y, Byrne B, Coulthard J. Sensing field homogeneity in mass flow rate measurement of pneumatically conveyed solids[J]. Flow Measurement and Instrument,1995,6(2):115-119.
[7]Armour-Chélu D I, Woodhead S R. Comparison of the electric charging properties of particulate materials in gas-solids flows in pipelines[J]. Journal of Electrostatics,2002,56(1):87-101.
[8]Coulthard J, Cheng R X,Keech R. Developments in pulverized fuel metering for coal-fired power stations[J]. Power Engineering,2000,14(6)100-104.
[9]吴建军,邵富群.工业烟道固体颗粒物排放量自动监测方法[J].仪表技术与传感器,2004,1(7):46-47.
[10]Hammer E A, Green R G. The spatial filter effect of capacitance transducer electrodes[J]. J Phys E: Sci Instrum,1983,16(5):438-443.
[11]阚哲.基于静电传感器气-固两相流参数测量方法研究[D].沈阳:东北大学,2010.