Abstract:To design a superconducting cavity with high quality factor for frequency standard, the parameters that affect the ability of the cavity are all achieved through theory analysis and computer program. A curve through which the temperature can be achieved for the aim is got through calculating the quality factor in different temperature. The parameters of cavity are as follows: the mode is TM010, the diameter is 60 mm, the height is 50 mm, the frequency is 4.4GHz, the quality factor is 3.9×107 and 1.9×109 when the temperature is 4.2K and 2K,respectively,which is close to the calculation.
王暖让,吴琼,杨仁福,年丰,高连山. 短稳标准高Q值超导腔的研究[J]. 计量学报, 2011, 32(1): 70-74.
WANG Nuan-rang,WU Qiong,YANG Ren-fu,NIAN Feng,GAO Lian-shan. Design of A Superconducting Microwave Cavity with High Quality Factor for Frequency Standard. Acta Metrologica Sinica, 2011, 32(1): 70-74.
[1]Blomfield D L H, Pointon A J. Short-term frequency stability of an L band oscillator with a superconducting cavity[J].Electronics Letters,1973, 9(19): 461-462.
[2]Ciovati G, Kneisel P. Preliminary results on the simultaneous excitation of the TM010 and TE011 modes in a single cell Niobium cavity[C]//IEEE Proceedings of 2005 Partical Accelerator Conference, Knoxville, 2005, 3844-3846.
[3]Buchman S, Turneaure J P, Lipa J A,et al.A superconducting microwave oscillator clock for use on the Space Station[C]//IEEE International Frequency Control Symposium, Californial, 1998, 534-539.
[4]郝建奎,焦飞,黄森林,等.提高射频超导加速腔性能的表面干式处理研究[J].物理学报,2005,54(7):3375-3379.
[5]葛明骐,赵生初,孙虹,等. 1.3 GHz单cell高梯度低损耗超导腔设计研究[J]. 高能物理与核物理, 2006, 30(4): 354-358.
[6]温华明,严陆光,林良真.超导在加速器中的应用概况[J].低温与超导, 2005, 33(1): 46-49.
[7]Pozar D M. 微波工程(3版)[M]. 张肇仪,等译. 北京:电子工业出版社, 2006, 245-246.