Studies on Three Driving Methods of Coriolis Mass Flowmeter
LI Miao1, XU Ke-jun1,2,ZHU Yong-qiang1,HOU Qi-li1,LI Ye1
1.School of Electrical and Automation Engineering, Hefei University of Technology, Hefei, Anhui 230009, China
2.Engineering Technology Research Center of Industrial Automation, Anhui Province, Hefei, Anhui 230009, China
Abstract:Aiming at the driving problem of Coriolis mass flowmeter, the driving methods of analog,semi-digital, and all-digital are compared and achieved . For Micromotion-CNG050 type Coriolis mass flow sensors, a secondary instrument is developed with DSP, to achieve the driving experiments. The problems in driving respectively is analyzed based on digital signal synthesis with digital devices. The experimental results show that the performance of them is improved gradually.
李苗,徐科军,朱永强,侯其立,李叶. 科氏质量流量计的3种驱动方法研究[J]. 计量学报, 2011, 32(1): 36-39.
LI Miao, XU Ke-jun,ZHU Yong-qiang,HOU Qi-li,LI Ye. Studies on Three Driving Methods of Coriolis Mass Flowmeter. Acta Metrologica Sinica, 2011, 32(1): 36-39.
[1]徐科军,于翠欣,苏建徽,陈荣保,刘家军. 科里奥利质量流量计激振电路的研制 [J]. 合肥工业大学学报,2002,23(1):37-40.
[2]徐科军,徐文福. 科氏质量流量计模拟驱动方法研究[J].计量学报,2005,26(2):149-154.
[3]徐科军,张瀚. 一种科氏流量计的数字信号处理与驱动方法研究[J]. 计量学报,2004,25(4):339-343,379.
[4]张瀚,徐科军. 新型数字式科氏质量流量变送器 [J].自动化仪表,2005,26(1):25-28.
[5]Henry M P, Clarke D W, Vignos J H, et al. Digital Flowmeter:U S,0038186A1[P]. 2002-03-28.
[6]Henry M P, Clarke D W, Vignos J H. Digital Flowmeter:US,6754594B2[P].2004-06-22.
[7]Clarke D W. Non-linear Control of the Oscillation Amplitude of a Coriolis Mass-Flow Meter [J]. European Journal of Control, 1998,4:196-207.
[8]Mayela Zamora, Henry M P. An FPGA Implementation of a Digital Coriolis Mass Flow Metering Drive System. [J]. IEEE Trans Ind Electron, 2008, 55(7): 2820-2831.
[9]Manus Henry. Self-validating digital Coriolis mass flow meter [J]. Computing & Control Engineering Journal, 2001,10:219-226.
[10]Henry M P, Zamora M E. Startup and Operational Techniques for A Digital Flowmeter:US,6950760B2[P].2005-08-27.
[11]Henry M P, Zamora M E. Startup and Operational Techniques for A Digital Flowmeter:US,7146280B2[P]. 2006-12-05.
[12]Henry M P, Clarke D W, Archer N, et al. A self-validating digital Coriolis mass-flow meter : an overview. [J]. Control Engineering Practice, 2000,8(5) :487-506.
[13]马金尼斯 R L.科里奥利流量计中用于驱动控制的初始化算法:中国,CN1418309[P].2003-05-14.
[14]Manus Henry, Michael Tombs,Mihaela Duta, et al.Two-phase flow metering of heavy oil using a Coriolis mass flow meter :A case study[J].Flow Measurement and Instrumentation, 2005, 17:399-413.