1. Automatic Measurement and Control, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
2. Institute of Metrology on Physics and Chemistry, Capital Aerospace Mechinery Company, Beijing 100076, China
Abstract:The relative positions and spatial attitudes of transmitters in Indoor GPS industry measurement system should be calibrated before the measurement being carried on. A single cylindrical sensor will be adopted combining a scale bar to obtain the azimuths and elevations of the transmitters at different spatial points in order to carry on the self-calibration. The transforming model of coordinate parameters based azimuth and elevation angles are established and calculated through least square algorithm of non-linear optimization to accomplish the self-calibration. Experiment testing shows that this calibration method is convenient and feasible.
[1]Indoor GPS Metrology Sytem with 3D Probe for.Precision Applications[EB]. http://www.arcsecond.com.
[2]吴晓峰,张国雄.室内GPS测量系统及其在飞机装配中的应用[J].航空精密制造技术.2006,42(5):1-5.
[3]Maisano D A, Jamshidi J. Indoor GPS: System functionality and initial performance evaluation[J]. International Journal of Manufacturing Research, 2008, 3(3):335-349.
[4]张光澄.非线性最优化计算方法[M]. 北京:高等教育出版社,2005,146-159.