Study on Ultrasonic Imaging Devices for Liquid-solid Two-phase Flow
ZHOU Ming1,2, SHAO Fu-qun1, ZHANG Lin1
1.College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning 110004, China;
2.College of Computer, Jilin Normal University, Siping, Jilin 136000, China
Abstract:To constitute a data acquisition system for ultrasonic projections, piezoelectric ultrasonic sensors, sensor array, sending and receiving circuits for ultrasound were made. With the liquid-solid two-phase flow of water and sediment as research object, the projection data were collected by a computer. It is found that resonance frequency of the sensor is up to 200kHz, launch angle of the launching sensor is bigger, and receiving sensitivity of the receiving sensor is higher. The electromagnetic interference produced in the receiving sensor is eliminated significantly by RC filter. The way of alternate arrangement of the sensors can make system to get the largest number of projection data, and make the design of circuits feasible to avoid mutual interference of signal. The projection data truly reflect the flow condition of solid phase.
[1] Huang S W, Li P C. Ultrasonic Computed Tomography Reconstruction of the Attenuation Coefficient Using a Linear Array[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005,52(11): 2011-2014.
[2] Sun L, Richard W D, Cannata J M, et al. A High-Frame Rate High-Frequency Ultrasonic System for Cardiac Imaging in Mice[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007,54(8): 1648-1654.
[3] Filho M M C, Machado J C. The Ultrasonic Attenuation Coefficient for Human Blood Plasma in the Frequency Range of 7~90MHz[C]//IEEE Ultrasonics Symposium 2004, Dresden, Germany, 2004, 2073-2075.
[4] 姚骏,张权,李斌. 基于超声衰减的纸浆浓度测量技术的研究[J]. 计量学报,2008,29(1): 87-90.
[5] 王艳霞,傅星,李正光,等. 高精度的超声波在线流量测量[J]. 计量学报,2003,24(3): 202-204.
[6] Nguyen T H, Khrakovsky O, Sui L. Transducer design for liquid custody transfer ultrasonic flowmetering[C]//IEEE Ultrasonics Symposium 2007, New York, US, 2007,1832-1835.
[7] Rahiman M H F, Zulkarnay Z, Rahim B A R. Ultrasonic process tomographic imaging sensor: an Approach utilising transceivers method[C]//Proceedings of the International Conference on Computer and Communication Engineering.2008, New York,US,2008,1147-1150.
[8]Carey S J, Lay L L, Hatfield J V. P2B-5 Integrated Amplifier Array for High Frequency Ultrasound[C]//IEEE Ultrasonics Symposium.2007,New York,US,2007,1518-1521.