Abstract:To separate the system error of precision stage, a new method for separation was put forward. Firstly different positions of auxiliary measuring grid plate and 2D-stage were measured. Then according to the measurement data of mark points on the grid plate and their corresponding nominal values, a mathematical model for error separation was established, which could separate errors from the measured results. The effectiveness of the algorithm was verified through simulation. Simulation results showed that when there was no measurement noise, the algorithm could realize complete error separation, while in the case of the presence of measurement noise, the relative error of standard deviation of calculated values and the given values were 1.95% and 1.52% in X-axis and Y-axis respectively. For noises with different amplitudes, the calculated values of system errors were stable. The algorithm is not sensitive to noise and can be very useful in evaluation of measurement results and instrument performances.
[1]青木保雄, 大园成夫. 三点法真圆度测定法の展开[J]. 精密机械, 1966, 32(12):27-32.
[2] 张雷, 赵莹, 张玉. 三测头法误差分离技术的理论与试验[J].机械工程学报, 2009, 45(6):256-261.
[3] 韩正铜, 洪迈生. 圆度误差分离的三点法及其演化形式与精度分析[J]. 机械设计与制造, 2002,(2):54-55.
[4] 杨洪寿, 费业泰, 陈晓怀,等. 纳米三坐标测量机的误差分析与分离[J]. 安徽理工大学学报, 2010, 30(3):36-40.
[5] Ye J, Takac M T, Berglund C N, et al. An exact algorithm for self-calibration of precision metrology stages[J]. Precision Engineering, 1997, 20(1):16-32.
[6] Raugh M R. Absolute two-dimensional sub-micron metrology for electron beam lithograph[J]. Precision Engineering, 1985, 7(1):3-13.
[7] Takac M T, Ye J, Pease R F, et al. Self-calibration in two dimensions: the experiment[J]. SPIE Digital Library, 1996, 2725: 130-146.
[8] 朱煜, 朱立伟, 尹文生, 等. IC加工及检测装备超精密工作台自标定技术研究[J].电子工业专用设备, 2005, 34(3):20-24.
[9] 朱立伟, 朱煜, 尹文生. 超精密二维工作台自标定技术研究[J]. 中国机械工程, 2005, 16(20):1787-1890.
[10] Zhu Y, Hu C X, Hu J C. Least-square based self-calibration of two-dimensional ultra-precision stages[C]//2011 International Conference on Mechatronics and Automation (ICMA), Beijing, China. 2011: 597-602.
[11] Zhu Y, Hu C X, Hu J C. A transitive algorithm for self-calibration of two-dimensional ultra-precision stages[C]//International Conference on Advanced Intelligent Mechatronics(AIM), Budapest, Hungary. 2011:594-598.
[12] Hu C X, Zhu Y, Hu J C, et al. A holistic self-calibration approach for determination of three-dimensional stage error [J]. Transactions on Instrumentation and Measurement, 2013, 62(2): 483-494.