Abstract:In order to ensure the consistency of UV transmittance values in China with those in the world, the National Institute of Metrology, China, participated in the first research comparison of ultraviolet regular transmittance organized by COOMET during 2018 to 2019. This comparison uses 4 sets of solutions as comparison samples, the nominal value of transmittance covers 5%~90%, and the wavelength range covers 235nm~350nm. The comparison results show that the measurement results of each reference laboratory are basically equivalent and consistent. When the transmittance is 50%, the deviation between ours and the international reference value can not exceed 0.12%. When the transmittance is near 20%, the deviation between ours and the international reference value is less than 0.08%. For 10% transmittance, the deviates quantity is no more than 0.03%.
FENG G, WANG Y, LI P, et al. Comparison of mid-infrared regular transmittance measurement [J]. Applied Mechanics and Materials, 2013, 239-240: 176-180.
GUO T. Elimination of System Drift in Transmittance Measurement [C]//International Conference on Mathematical, Physical and Engineering Sciences (MPES 2010). Penang, Malaysia, 2010.
Certification and use of acidic potassium dichromate solutions as an ultraviolet absorbance standard SRM 935[M]. US Department of Commerce,1977.
[8]
CHUNNILALL C J. NIST-NPL comparison of mid-infrared regular transmittance and reflectance [J]. Metrologia, 2003, 40: 55-59.
[10]
KAPLAN S G, HANSSEN L M, EARLY E A, et al. Intercomparison of regular spectral transmittance and reflectance measurements with FTIR-and monochromator-based spectrophotometers[C]//Optical Diagnostic Methods for Inorganic Materials II. San Diego, USA, 2000.
[12]
CHUNNILALL C J, CLARKE1 F J J, SMART M P, et al. NIST-NPL comparison of mid-infrared regular transmittance and reflectance [J]. Metrologia, 2003, 40(1): S55-S59.
[6]
HAAPALINNA A, MANOOCHEHRI F, IKONEN E. High-accuracy measurement of spectral reflectance and transmittance [J]. Analytica Chimica Acta, 1999, 380(2-3): 317.
XING D L, WU Y S, JIANG W J. Study on the standard material of spectral Transmittance [J]. Chemical analysis and Metrology, 2002, 11(6): 4.
JACKSON A, NASH B,IFARRAGUERRI A. Mid-infrared reflectance and transmittance measurements in the laboratory using field instruments[C]//Active and Passive Signatures. Orlando, FL, US,2010.
[13]
BURKE R W, MAVRODINEANU R.
[1]
ZWINKELS J C, GIGNAC D S. Automated high precision variable aperture for spectrophotometer linearity testing [J]. APPLIED OPTICS, 1991, 30(13): 1678-1687.
BAI S, LIN Y D, LYU L. Study on the influence of vacuum state on the transmittance of Brewster window [J]. Acta Metrologica Sinica, 2013, 34(6): 529-531.