Abstract:Superficial treatment has shown good advantages in the repair of postoperative scars and the treatment of skin lesions. In order to study the radiation quality produced by SRT-100 superficial X-ray therapy system, EGSnrc software was used to simulate the energy spectrum at different tube voltages, and the energy spectrum was compared with the energy spectrum calculated by Spekcalc program. The result showed good agreement between them. The effect of different target angles of the X-ray tube on the half-value layer was studied, and the result showed that the larger the target angle, the smaller the half-value layer. The mean energy and the effective energy were calculated from the simulated energy spectrum. Compared with the results of Spekcalc, results displayed that the maximum deviation of the average energy and the effective energy are 0.7% and 5.8% respectively.
GUO B, FAN C. Investigation of the Diagnostic X-ray RQR Series Establishment[J]. Acta Metrologica Sinica, 2011, 32 (z1): 45-47.
LU S L. Mechanism of scar formation and strategy of treatment[J]. Chinese Journal of Burns, 2013(2): 130-133.
XIA Y, WANG B, XU B. Surgical resection combined with postoperative radiotherapy for keloid treatment[J]. Journal of Chinese Practical Diagnosis and Therapy, 2008(11): 860-861.
MAO S R. XIAO Z B. Treatment Status and Research Progress of Pathologic Scars[J]. Chinese Journal of Aesthetic Medicine, 2022, 31(1): 181-184.
[7]
MA C M, COFFEY C W, DEWERD L A, et al. Report No. 076-AAPM protocol for 40~300 kV x-ray beam dosimetry in radiotherapy and radiobiology[J]. Med Phys, 2001, 28(6):868-893.
[10]
许淑艳. 蒙特卡罗方法在实验核物理中的应用[M]. 北京: 原子能出版社, 2006.
ZHAO R, WEN Y Q, WU J J, et al. The Establishment of Radiation Qualities and Energy Spectra Simulation of X-ray Lead Equivalent Measurement[J]. Acta Metrologica Sinica, 2022, 43(7): 960-964.
[13]
Radiological protection-X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—Part 1: Radiation characteristics and production methods :ISO 4037-1: 2019[S].
[17]
Rêgo F, Peralta L, Gomes M. Can the HVL help the mechanical X-ray tube characterization?[J]. X-Ray Spectrometry, 2011,40(4): 235-239.
CHEN S J, GUO R Z, ZHOU K M. Expressions and significances of CyclinA and CyclinA mRNA in skin scar and skin scar carcinoma[J]. The Journal of Practical Medicine, 2011, 27(17): 3121-3123.
[8]
KLEVENHAGEN S C, AUKETT R J, HARRISON R M, et al. The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mmAl-4 mm Cu HVL; 10~300 kV generating potential)[J]. Phys Med Biol, 1996, 41(12):2605-25.
[16]
Poludniowski G, Landry G, DeBlois F, et al. SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes[J]. Physics in medicine and biology, 2009, 54(19): N433-N438.
[18]
LEE Y C, DAVIS S D, ROMAGUERA W, et al. Implementation of superficial radiation therapy (SRT) using SRT-100 Vision TM for non-melanoma skin cancer in a Radiation Oncology clinic[J]. J Appl Clin Med Phys, 2023, 24(6): e13926.
[1]
陆树良. 瘢痕形成机制及治疗对策[J]. 中华烧伤杂志, 2013(2): 130-133.
LONG F, WANG X J. Research progress of radiotherapy for keloid[J]. Chinese Journal of Plastic Surgery,
[14]
姚馨博. X射线能谱测量与模拟[D]. 石家庄:河北科技大学, 2017.
[5]
XU J, YANG E, YU N Z, et al. Radiation Therapy in Keloids Treatment: History, Strategy, Effectiveness, and Complication[J]. Chinese Medical Journal ,2017, 130(14): 1715-1721.
[12]
IAEA . Calibration of reference dosimeters for external beam radiotherapy[R] No. 469, 2009.
[19]
REN-DIH S, POWERS A, YEH-CHI L. Commissioning a 50~100kV X-ray unit for skin cancer treatment[J]. Journal of Applied Clinical Medical Physics, 2015,16(2): 161-174.