Abstract:Residual chlorine is an important indicator for water quality monitoring and an important parameter for judging water quality.For this reason, the national second-class total residual chlorine reference materials GBW(E)084725, GBW(E)084726 were developed. According to the commonly used measurement methods of total residual chlorine, the method suitable for the calibration of reference materials was selected, and the methodology of the calibration method was studied. The homogeneity and stability of total residual chlorine reference materials with two concentrations were tested respectively. The F value of variance test was less than the critical value, indicating that the homogeneity of the reference material was good. During the six month stability investigation period, there was no statistically significant change in the reference materials with two contents. At the same time, ten day short-term high and low temperature simulation experiments were conducted. The results showed that there was no significant change statistically in the reference materials with two contents either, which indicated the stability of the two reference materials was good. The redox titration method was used for the determination of reference materials. The quantity values were 50mg/L and 500mg/L respectively, and the relative expanded uncertainty was 0.9% and 0.5% (k=2) respectively.
Chen H W, Xu S P, Li S F, et al. A Portable Analyzer for In-situ Rapid Determination of Free Chlorine and Total Chlorine [J]. Chinese Journal of Analytical Chemistry, 2003, 11 (31): 1399-1402.
Yu Y Q, Xu W Y. Discussion on the linear range of residual chlorine determination by spectrophotometry [J]. Shanghai Measurement and Testing, 2000, 19 (10): 495-496.
Wen W Y, Huang X P, Wu S Q, et al. Discussion on the Impact of Residual Chlorine in Cooling Water of Power Plants on the Marine Environmen [J]. Journal of Tropical Oceanography, 1993, 12 (3): 99-102.
Li L, Yang L, Ma L. Determination of Free Chlorine Residual in Drinking Water by Using N, N-diethyl-1, 4-phenylenediamine Spectrophotometry [J]. Poliution Control Technology, 2011, 24 (6): 76-78.
Guan M Y. Discussion on the Determination Method of Free Residual Chlorine in Drinking Wate [J]. Shanghai Journal of Preventive Medicin, 2003, 15 (11): 570-571.
ISO 7393-3-1990 Waterquality-Determination offree chlorineand totalchlorine—Part3: Iodometrie titration method for thedetermination of total chlorine[S].
[27]
全浩, 韩永志. 标准物质及其应用技术 (第2版)[M]. 北京: 中国标准出版社, 2003.
Wang Y, Xu S S, Guo B. Development of a standard substance for the analysis of chloride ions in water [J]. China Metrology, 2020 (1): 88-93.
Li M Y, Pan J, Xiong Y B. Recent Advances of Determination of Residual Chlorine in Water [J]. Environmental Monitoring in China, 2007, 23 (2): 40-42.
Chen J W, Ding M. General situation of the residual chlorine detecting methods and the residual chlorine reference material [J]. Chemical Enterprise Management, 2013(2): 80-82.
[6]
JJF 1609—2017 余氯测定仪校准规范[ S ].
Cao L C. Determination of esidual chlorine contained in water by DPD photometry [J]. Environmental Engineering, 2003, 21 (1): 65-66.
Hu M Z, He Q Z, Ren C Y. Development and application of residual chlorine test paper [J]. Journal of Shanghai Normal University (Natural Sciences), 2002, 31 (1): 98-100.
Wu X F, Chen W H. Exploration on Determination of Residual Chlorine in Drinking Water by Spectrophotometric Method Using DPD [J]. Journal of China Urban Water Association, 2004(2): 30-31.
Lin Q H. Residual chlorine in DPD spectrophotometric determination center [J]. Journal of Taiyuan Urban Vocational College, 2004(2): 30-31.
Wang D, Wei X, Wang H Y, et al. Improving and Suggestions for Determining Residual Chlorine in Cycle Water with DPD Photometry [J]. Petrochemical Industry Technology, 2006, 13 (2): 30-32.
Li Y B. Comparison of Two Residual Chlorine Determination Methods [J]. Jiangsu Journal of Preventive Medicine, 2003, 14 (4): 61-62.
Feng H T, Liu L. Determination of residual chlorine in raw and drinking water by TMB method [J]. Chinese Journal of Public Health Engineering, 2003, 2 (1): 43-44.
Liu L H, Yang H Q, Li X X, et al. Colorimetric determination of residual chlorine in water using a new type of chromogenic agent 3, 3, 5, 5-tetramethylbenzidine [J]. Chinese Journal of Public Health, 1994, 10 (1): 25-27.
Xu X J, Lin B, Chen Y Q. Determination of Free Chlorine with Spectrophotometric Method Using N, N-diethyl-1, 4-Phenylenediamine [J]. Spectroscopy and Spectral Analysis, 2004, 24 (10): 1235-1237.
Yang Z F. Researches on the optimization of determinating conditions of free residual chlorine in drinking water [J]. Industrial Water Treatment, 2000, 20 (8): 31-32.
Zhu G Q, Cai Y F, Xu J Q. Quality control and application of on-site determination of free residual chlorine with 3, 3, 5, 5 - tetramethylbenzidine [J]. Occupation and Health, 2003, 19 (4): 42-43.
Zhang J S, Zhang D F. Improvement of Determination Method for Free Residual Chlorine in Drinking Water [J]. Chinese Journal of Health Laboratory Technology, 2007, 17 (7): 1307-1308.
Ren B L, Ni H J, Zhang Q M. Improvement of standard detection method for residual chlorine [J]. Water Technology, 2008, 2 (6): 51-52.
Lian J, Chen Q Z, Zhao W T, et al. Determination of Residual Chlorine in Drinking Water by Clonal Hydrazine Colorimetry [J]. Chinese Journal of Disinfection, 1995, 12 (2): 116-l17.
[26]
GB/T 5750. 1—2006 生活饮用水标准检验方法消毒剂指标[S].
Liu Y Y, Zhang L, Yang Q S. Development of Reference Material for White Blood Cell Count in Urine Sediment [J]. Acta Metrologica Sinica, 2022, 43 (3): 427-432.
Li W R, Yang B, Huang Y J, et al. Development of Glucose in Human Serum Reference Material [J]. Acta Metrologica Sinica, 2021, 40 (5): 763-773.