Design and Experimental Research of Radial Magnetization Electromagnetic Sensor
TANG Bo1,2,GUO Bi-ben1,CHEN Wei2,TAN Long2
1. College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou, Zhejiang 310018, China
2. Ningbo Water Meter (Group) Co. Ltd, Ningbo, Zhejiang 315033, China
Abstract:A radially magnetized electromagnetic sensor is proposed for the detection of the defects of the traction steel strip, which can realize the accurate detection of the defects of the traction steel strip in-situ nondestructive. Based on the electromagnetic coupling and the magnetic properties of high magnetic permeability materials, an equivalent model of the radially magnetized electromagnetic sensor is established by using the finite element analysis method. The laws of influence of the magnitude of the magnetic induction at the measurement location of the magnetized electromagnetic sensor. Finally, a radially magnetized electromagnetic sensor is prepared on the basis of numerical simulation and to measure its performance, and it is further applied to the defect detection of traction steel strips. The experimental results show that the system can realize the broken strand with a resolution of 0.5mm. This demonstrated that a feasible solution is provided for the defect detection of traction steel strips.
Zhang D L, Zhang E C, Yan X L. Quantitative method for detecting internal and surface defects in wire rope [J]. NDT & E International, 2021, 119(3): 102405.
Ji Y Y, Liu Y N, Deng C X, et al. Research on the Testing of Adhesive Defects of Aeronautical Composites Based on ECT [J]. Acta Metrologica Sinica, 2019, 40(6): 952-957.
Tang B, Chen S S, Guo B B, et al. Fault diagnosis of rolling bearings based on migration of characteristic parameters [J]. Acta Metrologica Sinica, 2022, 43(3): 386-391.
Shi R, Wei Y J, Wang J D. Wire rope defects with the micro-magnetic NDT technology [J]. Acta Metrologica Sinica, 2015, 36(3): 303-308.
Xu P, Geng M, Fang Z, et al. Study on high-speed rail defect detection method based on combination of EC and MFL testing [J]. Journal of Mechanical Engineering, 2021, 57(18): 57-65.
Zhang Z C, Shen C Y, Zhu Z H, et al. Magnetic flux leakage combined with eddy current for non-ferromagnetic metal materials damage detection [J]. Chinese Journal of Scientific Instrument, 2021, 42(4): 150-159.
Raisutis R, Kazys R, Mazeika L, et al. Propagation of ultrasonic guided waves in composite multi-wire ropes [J]. Materials, 2016, 9(6): 451.
[11]
Sun Y H, Feng B, Liu S W, et al. A methodology for identifying defects in the magnetic flux leakage method and suggestions for standard specimens [J]. Journal of Nondestructive Evaluation, 2015, 34(3): 1-9.
Chang Y, Jiao J P, Li G H, et al. Influencesand optimization of excitation structure of magnetic flux leakage sensor [J]. Journal of Mechanical Engineering, 2018, 54(24): 7-17.
Carboni M, Crivelli D. An acoustic emission based structural health monitoring approach to damage development in solid railway axles [J]. International Journal of Fatigue, 2020, 139: 105753.
Yu Y D, Song K, Li G H, et al. Simulation and optimization of multichannel low frequency electromagnetic sensor [J]. Chinese Journal of Scientific Instrument, 2019, 40(10): 19-27.
Zhou D Q, Tian G Y, Wang H T, et al. Evaluation of applied stress using pulsed eddy current technology [J]. Chinese Journal of Scientific Instrument, 2010, 31(7): 1588-1593.
[10]
Lei H M, Tian G Y, Zhao H, et al. Health monitoring for coated steel belts in an elevator system [J]. Journal of Sensors, 2012, 2012(3): 276-283.
Yu X L, Xu K J, Xu W, et al. Development of electromagnetic water meter transmitter based on intermittent excitation and signal reconstruction [J]. Acta Metrologica Sinica, 2021, 42(9): 1160-1166.
Ren F A, Xu J X, You Q, et al. Thermal analysis of permanent-magnet system in the joule balance [J]. Acta Metrologica Sinica, 2019, 40(3): 353-360.