Abstract:In order to accurately measure low-energy and low-dose-rate X-ray, based on 10~60kV X-ray machine, seven reference radiation quality were established by adding additional filtration on the basis of low air kerma series radiation quality. The energy spectrum of radiation quality by Monte Carlo simulation program were obtained, and half-value layer and average energy were calculated. The proportional counter was used to complete the measurement of the energy spectrum. The results showed that the relative deviation between the simulated energy spectra and measured spectra does not exceed 6%. By used PTW34047 ionization chamber, the measurement of air kerma rate was completed by successive substitution method. The proportional counter was calibrated and the energy spectrum-dose conversion function was obtained. Finally, the energy spectrum-dose conversion function was verified, and the deviation from the results obtained by the ionization chamber method is not more than 3.8%. Verified by AT1123 survey meter, the relative deviation is within 9%.
秦峰,吴金杰,李梦宇,鲁平周,屈冰冰,焦志伟,汤显强,朱伟峰,赵瑞. 基于正比计数器的低能X射线空气比释动能测量研究[J]. 计量学报, 2023, 44(8): 1277-1283.
QIN Feng,WU Jin-jie,LI Meng-yu,LU Ping-zhou,QU Bing-bing,JIAO Zhi-wei,TANG Xian-qiang,ZHU Wei-feng,ZHAO Rui. Study on the Measurement of Low Energy X-ray Air Kerma Based on Proportional Counter. Acta Metrologica Sinica, 2023, 44(8): 1277-1283.
Zhao R, Wu J J, Fan S, et al. Establishment of environmental level X-ray radiation qualities and research of the calibration methods of monitoring instruments [J]. Acta Metrologica Sinica, 2018, 39(S1): 131-136.
Environment and Development, 2019, 31(11): 130-131
[5]
Beddingfield D H, Beyerle A, Russo P A, et al.
High-Preesure xenon ion chambers for gamma-ray spectroscopy in nuclear safeguards[J]. Nuclear Instruments and Methods in Physics Research A, 2003, 505(1/2): 474-477.
Akimov D Y, Burenkov A A, Churakov D L,et al. Development of High Pressure Xe Scintillation Proportional Counter for Experiments in “Low-Background” Physics[J]. Physics,1997,doi:10.48550/arXiv.hep-ex/9703011.
Zhang Y, Yang Y. A Method for Optimising the Gas Replacing Period of Sealed Proportional Counter [J]. Nuclear Electronics & Detection Technology, 2011, 31(11): 1292-1294.
Li M Y, Zhao R, Qu B B,et al. Establishment of low-dose rate X-ray radiation quality and calibration of the instruments [J]. Nuclear Techniques, 2022, 45(6): 61-67.
Song F, Zhao R, Ding W C,et al. Research on calibration method of X-ray environmental radiation monitoring instrument [J]. Acta Metrologica Sinica, 2021, 42(9): 1237-1243.
Guo S M, Liu Y, Wu J J, et al. Half Value Layer Measurem ent of Mammography X-ray Standard [J]. Acta Metrologica Sinica, 2018, 39(3): 410-413.
Wang P, Xing L T, Jiang W. Measurement and Research for the Filtered X-ray Radiation Quality of Low Air Kerma Rate Series [J]. Acta Metrologica Sinica, 2021, 42(4): 521-525.
Wang J W, Wei P, Ma B X, et al. Main Factors Affecting Measurement Results of the Half-value Layer of Diagnostic X-ray Testing Equipment [J]. Metrology Science and Technology, 2021, 65(8): 3-6+28.
Yao Y B, Ma D X, Yin A M,et al. Research Progress on Effects of Low Dose Ionizing Radiation on Human Health [J]. Radiation Proctection Billetin, 2020, 40(3): 1-8.
Peng F L. Application of radiation environmental monitoring in radiation environmental impact assessment [J].
Jang D Y, Park B H, Kang S Y, et al. A Cylindrical High-Pressure Xenon Chamber with Shielding Mesh[C]//IEEE. Nuclear Science Symposium Conference Record (NSS/MIC). Orlando, FL, 2009.
Zhang J Y, Liu Y F, Liu P, et al. Efficiency Monte Carlo Calculation of Proportional Counter Tube for Low-energy X-Ray Detecting [J]. Nuclear Electronics & Detection Technology, 2016, 36 (3): 312-315.
[16]
Bandalo V, Greiter M B, Brnner J, et al. ISO 4037: 2019 validation of radiation qualities by means of half-value layer and Hp(10) dosimetry [J]. Radiation Protection Dosimetry, 2019, 187(4): 438-450.
Dombrowski H, Neumaier S. Traceability of the PTB low-dose rate photon calibration facility [J]. Radiation Protection Dosimetry, 2010, 140(3): 223-233.
[19]
Neumaier S, Arnold D, Bohm J, et al. The PTB underground laboratory for dosimetry and spectrometry [J]. Applied Radiation & Isotopes, 2000, 53(1): 173-178.
Lu P Z, Wu J J, Li M Y,et al. Study on scatter radiation of low energy X-ray absorbed dose to water measurement [J]. Nuclear Techniques, 2022, 45(4): 33-40.
Zhang D L, Wu J J, Du H Y,et al. Establishment of X-ray Reference Radiation of Low Air-kerma Rate [J]. Nuclear Electronics & Detection Technology, 2018, 38 (2): 217-222.
Huang P, Wan Q, Dong W L, et al. Research on energy response correction method for NaI radiation detector based on spectrum-dose conversion function [J]. China Measurement & Test, 2022, 48(2): 124-128.
Duan X J, Wu J J, Yang Y D. The affect of X-rays tube parameters simulated by EGSnrc on low energy spectrum [J]. Acta Metrologica Sinica, 2011, 32(S1): 51-53
[20]
Neumaier S, Wojcik M, Dombrowski H, et al. Improvements of a low-level gamma-ray spectrometry system at the underground laboratory “UDO” [J]. Applied Radiation & Isotopes Including Data Instrumentation & Methods for Use in Agriculture Industry & Medicine, 2009, 67(5): 726-730.
Cao L, Li D H, Yang Y et al. Enery Spectrum to Dose Conversion Method Used in Environment Radiation Dose Measurement [J]. Journal of Isotopes, 2022, 35(4): 297-303.