Abstract:A simple implicit parameter calibration method is proposed. The transition matrix element which is also called implicit parameter is obtained from the relation between the calibration board feature points world coordinates and its corresponding distorted image coordinates. Then the measured image is restored to the world coordinate system for measuring which can be seen as the image obtained from the case that the camera perpendiculars to the measured plane and under the case of no distortion in the lens. This method is used in the rail wear image measurement. After field test, it shows that the image calibration accuracy reaches 0.2mm and accuracy of the measurement system is better than 0.5mm which meets the requirements of the standard.
[1] Zhang Z Y. Flexible camera calibration by viewing a plane from unknown orientations[C]//Proceedings of IEEE International Conference on Computer Vision. Colorado, USA, 1999:666-673.
[2] Hekkila J, Sliven O. A four-step camera calibration procedure with implicit image correction [C]//IEEE Conference on Computer Vision and Pattern Recognition. California, USA, 1997: 1106-1112.
[3] 孙军华,张广军,刘谦哲,等.结构光视觉传感器通用现场标定方法[J].机械工程学报, 2009, 45(3): 174-177.
[4] 邢德奎.计算机视觉中摄像机标定若干关键技术研究[D]. 南京:东南大学, 2009.
[5] Chen D, Wang Y, Zhang G. A new sub-pixel detector for grid target points in camera calibration[C]//20th Congress of International Commission for Optics.2005,188-192.
[6] 丁大尉,纪淑波,王立志.光电式钢轨磨损实时检测系统[J].中国铁道科学, 2006, 27(1): 64-67.
[7] Alippi C, Casagrande E, Scotti F, et al. Composite Real-Time Image Processing for Railways Track Profile Measurement[J]. IEEE Transaction on Instrumentation and Measurement, 2000, 49[3]: 559-564.