2025年05月10日 星期六 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2023, Vol. 44 Issue (7): 1009-1018    DOI: 10.3969/j.issn.1000-1158.2023.07.01
  几何量计量 本期目录 | 过刊浏览 | 高级检索 |
多边法坐标测量系统关键布局参数对测量精度影响的研究
梁楚彦1,缪东晶2,李建双2,孔明1,李连福2,王德利2,刘洋2
1.中国计量大学计量测试工程学院,浙江 杭州 310018
2.中国计量科学研究院,北京 100029
Research on Influence of Key Layout Parameters on Measurement Accuracy in Multilateration System
LIANG Chu-yan1,MIAO Dong-jing2,LI Jian-shuang2,KONG Ming1,LI Lian-fu2,WANG De-li2,LIU Yang2
1. Collage of Metrology and Measurement Engineering, China Jiliang University, Hangzhou, Zhejiang 310018, China
2. National Institute of Metrology, Beijing 100029, China
全文: PDF (87140 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 为研究多边法坐标测量系统中测站相互位置关系对测量精度的影响,从坐标解算公式推导出测距误差的传递模型。分析了模型中误差放大因子及测站布局参数相关的数学公式,从该公式得出在一定范围内增大2个关键布局参数可改善系统测量精度,并通过仿真及实验进行验证。实验结果表明,关键布局参数从1m增至3m,系统的重复性误差可从20μm降至10μm,具有明显优化效果。同时,实验比较了布局参数相近但测站位置相差1m至3m的多个布局系统,在参数接近不变的条件下,测站位置差异几乎不影响系统的测量精度,说明该方法可改善系统的测量精度且具备灵活性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
梁楚彦
缪东晶
李建双
孔明
李连福
王德利
刘洋
关键词 计量学;大尺寸;坐标测量;多边法;布局优化测站位置误差放大因子    
Abstract:To study the influence of stations mutual position relationship on the measurement accuracy of multilateration system, an error transfer model was derived from the coordinate solution formula.The formula related to the error amplification factor and the station layout parameters in the model are studied and analyzed.From this formula, it can be concluded that increasing two key layout parameters within a certain range can improve the measurement accuracy of the system, which has been verified through simulation and experiments. The experimental results showed that the repeatability error of the system can be reduced from 20μm to 10μm when the key layout parameters were increased from 1m to 3m, and the optimization effect was obvious. Meanwhile, the systems with similar layout parameters had been compared, whose stations were at different locations. The results showed that the different locations of stations in system rarely affected the system precision while systems layout parameters were almost consistent, and suggested that method proposed can improve the measurement accuracy and had flexibility.
Key wordsmetrology    large scare    coordinate measurement    multilateration    layout optimization    stations position    error amplification factor
收稿日期: 2023-01-09      发布日期: 2023-07-17
PACS:  TB92  
基金资助:国家重点研发计划(2021YFF0600205);中国计量科学研究院基本科研业务费(AKYZZ2103)
通讯作者: 缪东晶(1985-),男,福建周宁人,中国计量科学研究院副研究员,主要从事大尺寸计量技术与自动化测量技术方面的研究。Email: miaodj@nim.ac.cn     E-mail: miaodj@nim.ac.cn
作者简介: 梁楚彦(1998-),男,广东番禺人,中国计量大学硕士研究生,主要研究方向为大尺寸坐标测量。Email: liangcuoyin@163.com
引用本文:   
梁楚彦,缪东晶,李建双,孔明,李连福,王德利,刘洋. 多边法坐标测量系统关键布局参数对测量精度影响的研究[J]. 计量学报, 2023, 44(7): 1009-1018.
LIANG Chu-yan,MIAO Dong-jing,LI Jian-shuang,KONG Ming,LI Lian-fu,WANG De-li,LIU Yang. Research on Influence of Key Layout Parameters on Measurement Accuracy in Multilateration System. Acta Metrologica Sinica, 2023, 44(7): 1009-1018.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2023.07.01     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2023/V44/I7/1009
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn