Abstract:Aiming at the problem that it is difficult to find the stable feature point in the signal processing of ultrasonic gas flowmeters,from the angle of the energy of the echo signal,the change rule of the echo signal energy is studied.The middle part of the rising segment of the contour of the echo energy signal is relatively stable,and the slope of the envelope of the middle part is the largest,which is approximately a straight line.A signal processing method based on echo energy peak point fitting is proposed.That is,firstly,the adjacent peak points of the rising segment of the echo energy signal are connected and the slope of each connected line is obtained,then four connected lines with larger slope are selected as the characteristic straight lines,and the right end points corresponding to the four characteristic straight lines are taken as the characteristic peak points to fit a straight line.Finally,the intersection point between the fitted straight line and x-axis is taken as the feature point,so as to calculate the ultrasonic propagation time.This signal processing method is implemented on the dual core system based on FPGA and DSP,and the calibration test is executed in the qualified testing institution.The results show that: the dual-channel ultrasonic gas flowmeter system based on the signal processing method of echo energy peak fitting achieves the 1.0-level accuracy,and the flow measurement range is 30~1200m3/h.
马杰,徐科军,江圳,张伦,徐浩然. 基于超声回波能量峰值点拟合的气体超声波流量计信号处理方法[J]. 计量学报, 2022, 43(5): 597-602.
MA Jie,XU Ke-jun,JIANG Zhen,ZHANG Lun,XU Hao-ran. A signal processing method of ultrasonic gas flowmeter based on peak point fitting of ultrasonic echo energy. Acta Metrologica Sinica, 2022, 43(5): 597-602.
[1]Jacobson S. New Developments in Ultrasonic Gas Analy-sis and Flowmetering[C]//Ultrasonics Symposium, 2008. Ius. IEEE, 2009: 508-516.
[2]Mylvaganam K S. High-rangeability Ultrasonic Gas Flow-meter for Monitoring Flare Gas[J]. IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control, 1989, 36 (2): 144-149.
[3]赵伟国,卜勤超,姚海滨, 等. 基于双声道的低压超声气体流量计数据融合方法[J]. 计量学报, 2021, 42 (7): 873-878.
Zhao W G, Bu Q C, Yao H B, et al. A Data Fusion Method of Double-channel Ultrasonic Flowmeter Application in Low Pressure Gas[J]. Acta Metrologica Sinica, 2021, 42 (7): 873-878.
[3]刘博, 徐科军, 穆立彬, 等. 基于Kalman滤波的气体超声波流量计融合方法[J]. 计量学报, 2018, 39 (6): 868-873.
Liu B, Xu K J, Mu L B, et al. Fusion Method of Ultrasonic Gas Flowmeter Based on Kalman Filter[J]. Acta Metrologica Sinica, 2018, 39 (46): 868-873.
[4]Lynnworth L C, Liu Y. Ultrasonic Flowmeters: Half-century Progress Report, 1955—2005[J]. Ultrasonics, 2007, 44 (1): e1371-e1378.
[5]Zhu W J, Xu K J, Fang M, et al. Mathematical Modeling of Ultrasonic Gas Flow Meter Based on Experi-mental Data in Three Steps[J]. IEEE Transactions on Instrumentation & Measurement, 2016, 65 (8): 1726-1738.
[6]Kupnik M, Oleary P, Scgroder A, et al. Numerical Simulation of Ultrasonic Transit-time Flowmeter Perfor-mance in High Temperature Gas Flows[C]//Ultr-asonics, 2003 IEEE Symposium on, 2003, 2: 1354-1359.
[7]Kobayashi T, Shigeta K, Fujii T. Transit-time Difference Type Ultrasonic Flowmeter: US6647805B2 [P]. 2003-06-05.
[8]Zhu W J, Xu K J, Fang M, et al. Variable Ratio Thre-shold and Zero-crossing Detection Based Signal Processing Method for Ultrasonic Gas Flowmeter[J]. Measurement, 2017, 103: 343-352.
[9]田雷, 徐科军, 沈子文, 等. 基于回波峰值拟合的气体超声流量计信号处理[J]. 电子测量与仪器学报, 2017, 31 (7): 1107-1114.
Tian L, Xu K J, Shen Z W, et al. A Signal Processing Method for Ultrasonic Gas Flowmeter Based on Peak Fit-ting of Rising Echo[J]. Journal of Electronic Measure-ment and Instruments, 2017, 31 (7): 1107-1114.
[10]张伦, 徐科军, 穆立彬, 等. 基于超声回波信号包络拟合的信号处理方法[J]. 电子测量与仪器学报, 2019, 33 (8): 194-201.
Zhang L, Xu K J, Mu L B, et al. Signal processing method based on ultrasonic echo signal envelope fitting[J]. Journal of Electronic Measurement and Instru-ments, 2019, 33 (8): 194-201.
[11]沈子文, 徐科军, 方敏, 等. 基于能量变化率的气体超声波流量计信号处理方法[J]. 仪器仪表学报, 2015, 36 (9): 2138-2144.
Shen Z W, Xu K J, Fang M, et al. Rate of energy based signal processing method of ultrasonic gas flow-meter[J]. Chinese Journal of Scientific Instrument, 2015, 36 (9): 2138-2144.
[12]Tian L, Xu K J, Mu L B, et al. Energy Peak Fitting of Echo Based Signal Processing Method for Ultrasonic Gas Flow Meter[J]. Measurement, 2018, 117: 41-48.
[13]江圳, 徐科军, 马杰, 等. 基于动态可变阈值的低功耗单声道气体超声波流量计[J]. 计量学报, 2022, 43 (3): 360-369.
Jiang Z, Xu K J, Ma J, et al. Low-power and Mono Gas Ultrasonic Flowmeter Based on Dynamic Variable Threshold[J]. Acta Metrologica Sinica, 2022, 43(3): 360-369.
[14]Fang M, Xu K J, Zhu W J, et al. Energy Transfer Model and Its Applications of Ultrasonic Gas Flow-meter Under Static and Dynamic Flow Rates[J]. Review of Scientific Instruments, 2016, 87 (1): 015107-1-015107-10.
[15]Liu B, Xu K J, Mu L B, et al. Echo energy integral based signal processing method for ultrasonic gas flow-meter[J]. Sensor and Actuators A: Physical, 2018, 277: 181-189.
[16]徐科军, 方敏, 汪伟, 等. 一种基于FPGA和DSP的气体超声流量计: CN104697593A [P]. 2017-12-08.
[17]穆立彬, 徐科军, 刘博, 等. 基于可变阈值和过零检测的四声道气体超声波流量变送器[J]. 计量学报, 2019, 40 (2): 266-271.
Mu L B, Xu K J, Liu B, et al. Development of Four-channel Ultrasonic Gas Flow Transmitter Based on Variable Threshold and Zero-Crossing Detection[J]. Acta Metrologica Sinica, 2019, 40 (2): 266-271.
[18] JJG 1030—2007 超声波流量计检定[S]. 2007.