Abstract:Diluted standard solution is often used for calibration of chemical analysis instruments.The uncertainty of dilution solution is the main component of the uncertainty of calibration instruments,which directly affects the final evaluation results.Taking 10mg/L and 50mg/L standard solutions for infrared oil meter as examples,the uncertainty of dilution solution is evaluated by mathematical method and empirical method respectively, and the influence of the two methods on the final results is analyzed. The results show that the evaluation results of the two methods are different, but the difference is not big. When evaluating the calibration uncertainty of instruments, different methods should be selected according to different accuracy requirements.
孙喜荣,黄金梅. 不同方法评定标准溶液稀释不确定度对仪器校准结果的影响及分析[J]. 计量学报, 2021, 42(11): 1517-1521.
SUN Xi-rong,HUANG Jin-mei. Influence and Analysis of Different Methods to Evaluate Uncertainty of Standard Solution Dilution on Instrument Calibration Results. Acta Metrologica Sinica, 2021, 42(11): 1517-1521.
[1]JJF 1059.1—2012 测量不确定度评定与表示[S].
[2]王朋朋, 赵士伟, 杨健, 等. 基于重量稀释法的海水盐度测量标准不确定度研究 [J]. 计量学报, 2019, 40 (5): 924-928.
Wang P P, Zhao S W, Yang J, et al. Uncertainty Research of the Seawater Salinity Measurement Standard Based on Weight Dilution Method [J]. Acta Metrologica Sinica, 2019, 40 (5): 924-928.
[3]刘园园, 杨健, 赵希勇, 等. GUM法和MCM法评定测量不确定度对比分析 [J]. 计量学报, 2018, 39 (1): 135-139.
Liu Y Y, Yang J, Zhao X Y, et al. Comparative Analysis of Uncertainty Measurement Evaluation with GUM and MCM [J]. Acta Metrologica Sinica, 2018, 39 (1): 135-139.
[4]秦婷, 苏庆, 邹琴. 微波消解ICP-MS法测定化妆品中镉的不确定度评定 [J]. 计量技术, 2019 (2): 14-17.
Qin T, Su Q, Zou Q. Evaluation of Uncertainty in Determination of Cd in Cosmetics Using Microwave Dig-estion ICP-MS [J]. Measurement Technique, 2019 (2): 14-17.
[5]赵金, 常俊斌, 宁凡盛, 等. 高效液相色谱-串联质谱法测定牛奶中磺胺类药物残留测量结果的不确定度评定 [J]. 计量技术, 2018(11): 64-67.
Zhao J, Chang J B, Ning F S, et al. Uncertainty Evaluation of Determination Results of Sulfonamides Re-sidues in Milk by High Performance Liquid Chromatograp-hyTandem Mass Spectrometry [J]. Measurement Techni-que, 2018(11): 64-67.
[6]张学英. 碳酸钠标准滴定液两种不确定度评定法的比较 [J]. 计量技术, 2018 (5): 13-17.
Zhang X Y.Comparison of two uncertainty evaluation methods for sodium carbonate standard titrant [J]. Measurement Technique, 2018 (5): 13-17.
[7]付川, 史乃捷, 冯流星, 等.牛肝标准物质中氯含量的定值方法研究 [J]. 计量学报, 2019, 40 (6): 1129-1134.
Fu C, Shi N J, Feng L X, et al. Determination of Chlorine in Bovine Liver Reference Material [J]. Acta Metrologica Sinica, 2019, 40 (6): 1129-1134.
[8]黎虹, 李光. 原子荧光形态分析仪的校准方法及不确定度评定 [J]. 化学分析计量, 2018, 27 (2): 96-99.
Li H, Li G. Calibration method of atomic fluorescence speciation analyzer and uncertainty evaluation [J]. Che-mical Analysis and Meterage, 2018, 27 (2): 96-99.
[9]王力君, 张明, 陈秀娜. 扩散分光光度法测定蒜粉成分分析标准物质中氟化物不确定度评定 [J]. 化学分析计量, 2021, 30 (7): 79-83.
Wang L J, Zhang M, Chen X N. Evaluation on uncertainty for determination of fluoride in certified refe-rence materials for composition analysis of garlic powder by diffusion spectrophotometric [J]. Chemical Analysis and Meterage, 2021, 30 (7): 79-83.
[10]丛文龙, 张贝贝, 王晓晓, 等.基于光化学反应的便携式血糖分析仪示值误差的不确定度评定 [J]. 计量与测试技术, 2021, 48 (6): 109-110.
Cong W L, Zhang B B, Wang X X, et al.Uncertainty Evaluation of the Portable Blood Glucose Analyzer Based on Photochemical Reaction [J]. Metrology & Measure-ment Technique, 2021, 48 (6): 109-110.
[11]王鹏, 赵荣林, 凌凤香, 等. ICP-AES法测定原油中镍含量及不确定度评定 [J]. 计量学报, 2021, 42 (6): 822-827.
Wang P, Zhao R L, Ling F X, et al.Determination of Nickel Content in Crude Oil by ICP-AES and Evaluation of Uncertainty [J]. Acta Metrologica Sinica, 2021, 42 (6): 822-827.
[12]张志超, 袁晓转, 韩慧丽.HPLC法测定盐酸利多卡因注射液含量的不确定度评定 [J].中国药物评价, 2021, 38 (3): 202-205.
Zhang Z C, Yuan X Z, Han H L. Uncertainty Evaluationon of the Content Determination of Lidocaine Hydrochloride Injection by HPLC [J]. Chinese Journal of Drug Evaluation, 2021, 38 (3): 202-205.
[13]孙迎迎, 余用. 碘量法测定水中溶解氧不确定度的评定 [J]. 化工管理, 2021 (17): 54-56.
Sun Y Y, Yu Y.Evaluation and Analysis of Uncertainty for Dissolved Oxygen in Water by Iodimetry [J]. Che-mical Enterprise Management, 2021 (17): 54-56.
[14]陈超, 罗建明, 胡雅忠, 等. 热重分析仪质量、温度示值误差不确定度评定 [J]. 计量与测试技术, 2021, 48 (5): 111-113.
Chen C, Luo J M, Hu Y Z, et al. Evaluation of Uncertainty in Indication Error of Quality and Tempera-ture of Thermogravimetric Analyzer [J]. Metrology & Measurement Technique, 2021, 48 (5): 111-113.
[15]JJG 950—2012 水中油分浓度分析仪[S].