1. School of Energy Power and Mechanical Engineering, North China Electric Power University, Baoding,
Hebei 071003, China
2. HuaDian Electric Power Research Institute Co. Ltd, Hangzhou, Zhejiang 310030, China
Abstract:The on-line measurement of SO3 is studied based on ultraviolet absorption spectroscopy, and SO3 gas generation system is built. In order to improve the detection accuracy, various interference factors in the measurement process are removed. The characteristic absorption bands of SO3 and SO2 overlap seriously, and the influence of SO2 on SO3 measurement can be removed to the greatest extent through reasonable selection of characteristic absorption bands and spectral inversion strategy. In the study, the standard curve method combined with single wavelength method, dual wavelength method and integral spectrum method is used to establish the standard curve. The results show that the measurement error of the integrated spectrum method is the smallest, and it can be preferentially applied to the on-line spectrometric analysis of SO3 emission.
[1]Belo L P, Elliott L K, Stanger R J, et al. Hightem-perature conversion of SO2 to SO3: homogeneous experi-ments and catalytic effect of fly ash from air and oxyfuel firing [J]. Energy Fuels, 2014, 28 (11): 7243-7251.
[2]Wang X P, Liu X W, Li D, et al. Effect of steam and sulfur dioxide on sulfur trioxide formation during oxy-fuel combustion [J]. Int J Greenhouse Gas Control, 2015, 43: 1-9.
[3]Sporl R, Walker J, Belo L, et al. SO3 emissions and removal by ash in coal-fired oxy-fuel combustion [J]. Energy Fuels.2014, 28 (8): 5296-306.
[4]惠润堂, 韦飞, 王宝德, 等. SCR法烟气脱硝后空气预热器堵塞及应对措施 [J]. 中国电力, 2014, 47(10): 110-112.
Hui R T, Wei F, Wang B D, et al. Analysis and Prevention of SCR DeNOx-Caused Air Preheater Clogging [J]. Electric Power, 2014, 47(10): 110-112.
[5]Fateev A, Clausen S. Sulfur trioxide measurement techni-que for SCR units[M]. Copenhagen: The Danish Envir-onmental Protection Agency, 2016.
[6]陈朋. 钙基吸收剂脱除燃煤烟气中SO3的研究 [D]. 济南:山东大学, 2011.
[7]Li Z, Jiang J, Ma Z, et al. Effect of selective catalytic reduction (SCR) on fine particle emission from two coal-fired power plants in China [J]. Atmos Environ, 2015, 120: 227-33.
[8]GB/T 34605—2017 燃煤烟气脱硫装备运行效果评价技术要求 [S].
[9]Fleig D, Vainio E, Andersson K, et al. Evaluation of SO3 measurement techniques in air and oxyfuel combu-stion [J]. Energy Fuels, 2012 , 26 (9): 55, 37-49.
[10]王金袖.燃煤电厂三氧化硫排放在线监测技术研究 [D]. 保定:华北电力大学, 2019.
[11]郑海明, 李长朝.基于高温还原及差分吸收光谱监测烟气汞的实验研究 [J]. 计量学报, 2017, 38 (6): 780-785.
Zheng H M, Li C Z. Research on Flue Gas Mercury Based on High Temperature Reduction and Differential Absorption Spectroscopy [J]. Acta Metrologica Sinica, 2017, 38 (6): 780-785.
[12]郑海明, 靳伟佳.温度对二氧化硫紫外吸收特性的影响 [J]. 光谱学与光谱分析, 2013, (3): 776-779.
Zheng H M, Jin W J. Effects of Temperature on the Ultraviolet Absorption Characteristics of SO2 [J]. Spectroscopy and Spectral Analysis, 2013, (3): 776-779.
[13]王金涛, 陈超云, 李志昊, 等.超微量液体容积双波长参比测量方法研究 [J]. 计量学报. 2015, 36 (3): 256-259.
Wang J T, Chen C Y, Li Z H, et al. Study on Dual-wavelength Photometric Method for Ultra Micro Liquid Volume Measurement [J]. Acta Metrologica Sinica, 2015, 36 (3): 256-259.
[14]李冰莹, 李永新, 马宇明, 等.从“随机过程”的角度认识测量误差及其分类 [J]. 计量学报, 2018, 39 (2): 285-288.
Li B Y, Li Y X, Ma Y M, et al. The Cognition of Measurement Error and Classification from the Perspec-tive of “Stochastic Process” [J]. Acta Metrologica Sinica, 2018, 39 (2): 285-288.
[15]吴丹, 张国城, 赵晓宁. 光散射法颗粒物监测仪粒径识别检测装置的搭建及方法研究 [J]. 计量学报, 2021, 42 (3): 388-394.
Wu D, Zhang G C, Zhao X N. Research on Con-struction and Method of Particle Size Recognition and Detection Device for Light Scattering Particles Monitor [J]. Acta Metrologica Sinica, 2021, 42 (3): 388-394.
[16]钟家栋, 孙斌, 赵玉晓, 等. 基于静力称重法的微小容量光学检测系统标定 [J]. 计量学报, 2020, 41 (8): 960-964.
Zhong J D, Sun B, Zhao Y X, et al. Calibration Method for Optical Measurement of Ultra-Micro Liquid Volume [J]. Acta Metrologica Sinica, 2020, 41 (8): 960-964.
[17]何映锋, 邓乐武, 吴杰, 等. 基于分段线性法的红外辐射计响应度标定研究 [J]. 计量学报, 2020, 41 (6): 646-649.
He Y F, Deng L Y, Wu J, et al. Spectral responsivity Calibration of Infrared Radiometer Based on Piecewise Linear Calibration Method [J]. Acta Metrologica Sin-ica, 2020, 41 (6): 646-649.